Texas Heart Institute journal
-
Multicenter Study
Acute surgical pulmonary embolectomy: a 9-year retrospective analysis.
Acute pulmonary embolism is a substantial cause of morbidity and death. Although the American College of Chest Physicians Evidence-Based Clinical Practice Guidelines recommend surgical pulmonary embolectomy in patients with acute pulmonary embolism associated with hypotension, there are few reports of 30-day mortality rates. We performed a retrospective review of acute pulmonary embolectomy procedures performed in 96 consecutive patients who had severe, globally hypokinetic right ventricular dysfunction as determined by transthoracic echocardiography. ⋯ Comparable findings for hemodynamically unstable patients were 12.5% and 13.4 days, respectively. Acute pulmonary embolectomy can be a viable procedure for patients with severe, globally hypokinetic right ventricular dysfunction, with or without hemodynamic compromise; however, caution is warranted. Our outcomes might be dependent upon institutional capability, experience, surgical ability, and careful patient selection.
-
Case Reports
Incidental left atrial blood cyst in a patient undergoing transcatheter aortic valve replacement.
Blood cysts of the heart are benign cardiovascular tumors found incidentally in approximately 50% of infants who undergo autopsy at less than 2 months of age. These congenital cysts, frequently present on the atrioventricular valves of infants, are exceedingly rare in adults. Nonetheless, in adults, cardiac blood cysts have been found on the mitral valve, papillary muscles, right atrium, right ventricle, left ventricle, and aortic, pulmonic, and tricuspid valves. ⋯ The embolic risk of rapid pacing and transcatheter aortic valve replacement in a patient with an intracardiac blood cyst is unknown, and such a case has not, to our knowledge, been reported heretofore. We present the case of a 78-year-old woman with severe aortic stenosis, in whom a blood cyst was incidentally found in the left atrium upon transesophageal echocardiography. She underwent successful transcatheter aortic valve replacement without embolic complication.
-
Case Reports
Early detection of a cavopulmonary tumor embolus with the use of transesophageal echocardiography.
Pulmonary tumor embolization from renal cell carcinoma is associated with severe cardiopulmonary morbidity and high perioperative mortality rates. We report the case of a 71-year-old woman who presented with right-sided abdominal pain. Magnetic resonance images revealed a mass originating from the upper pole of the right kidney and extending into the infrahepatic portion of the inferior vena cava. ⋯ After emergent sternotomy and during the initiation of cardiopulmonary bypass, the mass was no longer echocardiographically detectable in the heart; it was soon removed completely from the left pulmonary artery. The mass was a renal cell carcinoma. We recommend the use of transesophageal echocardiography as an efficient diagnostic tool in the early detection of pulmonary tumor embolization during the resection of renal cell carcinoma that involves the inferior vena cava.
-
Determining aortic stenosis (AS) severity is clinically important. Calculating aortic valve (AV) area by means of the continuity equation assumes a circular left ventricular outflow tract (LVOT). The full impact of this assumption in calculating AV area is unknown. ⋯ Using the modified method reduces mischaracterizations of AS severity. Congenital AV morphology and low cardiac index predict horizontal-oval or noncircular shape. These data suggest the value of direct LVOT measurement to calculate AS severity in patients who have congenital AV or a low cardiac index.
-
We report the successful implantation of a HeartMate II left ventricular assist device after a failed Fontan procedure in a patient with dextro-transposition of the great arteries. The patient had developed significant intrapulmonary arteriovenous shunting. ⋯ He was discharged from the hospital in stable condition and had better oxygen saturation than before the device was implanted. To our knowledge, ours is the 2nd report of the use of a ventricular assist device after the failure of a Fontan procedure, and the first report concerning the effect of ventricular assist device implantation on intrapulmonary shunting.