Nefrología : publicación oficial de la Sociedad Española Nefrologia
-
The current definition and classification of acute kidney injury is based on consensus criteria (RIFLE and AKIN systems). Creatinine is the most commonly used of the recommended parameters (creatinine, glomerular filtration rate and diuresis). If the baseline value is not known, it can be calculated based on the simplified MDRD equation, assuming a filtration rate of 75 ml/min/1.73 m2 for the calculation. The aim of this study was to evaluate the diagnostic impact of using estimated baseline creatinine compared to the actual value measured in patients undergoing cardiac surgery. ⋯ The calculation of baseline creatinine using the MDRD equation overestimates the incidence of acute kidney injury after cardiac surgery, and is an inadequate method for detection when the baseline value is unknown.
-
Periodic blood flow (QA) measurement is the preferred way for arteriovenous fistula (AVF) surveillance in chronic hemodialysis (HD) patients. Objectives. 1) Assess the efficacy of the temperature gradient method (TGM) on the QA determinations using the Twister™ device and to compare the functional results with the Delta-H method. 2) Evaluate the effect of blood pressure on the AVF function. Patients and method. We measured the QA non invasively in 30 AVF (24 radial and 6 brachial; mean duration 53.4 +/- 78.5 months) during HD in 30 stable patients (mean age 59.9 +/- 14.1 years, males 60 %, females 40 %; mean time on HD 37.4 +/- 40.6 months, diabetic nephropathy 20 %) by the TGM, described and validated by Wijnen et al (Kidney Int 2007;72:736). The QA was calculated from the temperature values obtained by means of the blood temperature monitor (BTM), integrated into the Fresenius Medical Care 4008-S machine, at normal and reverse configurations of the HD blood lines, with no need for a thermal bolus. The Twister™ device was used for reversing the blood lines without the need to disconnect them from the AVF lines nor to stop the blood pump. The QA was measured within the first hour of two consecutive HD sessions (the values were averaged). The mean arterial pressure MAP (diastolic pressure + 1/3 pulse pressure) was calculated simultaneous with the QA. In addition, the AVF blood flow was also determined during the same week in all patients by the Delta-H method using the Crit-Line III Monitor (ABF-mode, HemaMetrics, USA) during HD (manually switching lines). ⋯ 1) The TGM is a valuable and reproducible indicator of QA during HD. 2) The Twister™ device is useful to reduce the time for QA measurement by the TGM. 3) The AVF blood flow values obtained by the TGM and the Delta-H technique correlated highly with each other. 4) It has been shown the lack of relationship between the AVF function and the patient's blood pressure.
-
Acute renal failure (ARF) occurs in 12%-20% of all multiple myeloma (MM) cases, and the survival of these patients depends on renal function recovery. Renal function is not recovered in 75% of dialysis-dependent patients, and their mean survival with replacement therapy is less than one year. Renal tubular disease is the most frequent cause of renal failure. It is present in more than 55% of renal failure cases and in 75% of those requiring dialysis. Rapid reduction of free light chain levels in the blood is necessary in order to recover renal function. One coadjuvant measure in treating the disease is reducing light chain levels with plasmapheresis, but its efficacy has not yet been clearly proven. Our proposal was therefore to use extended haemodialysis sessions with high cut-off dialysers (HCO-HD), obtaining a recovery rate of more than 60%. We present the progress of 6 patients with myeloma and acute renal failure who were treated with HCO-HD and the complications associated with using this type of haemodialysis. Then, we review the pros and cons of this technique. ⋯ We found extended haemodialysis with HCO-HD filters to be a reasonable alternative in ARF caused by renal tubular disease, and achieved a recovery rate of 50% in our cases. Function recovery was influenced by the elapsed time between symptom onset and myeloma diagnosis, histological findings, promptness of starting chemotherapy, response to chemotherapy, and effectiveness of light chain extraction. In any case, further studies are needed to examine new chemotherapy agents and new direct free light chain removal techniques.
-
Randomized Controlled Trial
Evaluation of coagulation and anti-Xa factor when using a heparin-coated AN69ST® dialyser.
Hemodialysis systems are potentially thrombogenic, so it is routinely used anticoagulation. Its prescription is with risks though which the recommendations regarding the scheduled dose are still based on very different criteria. ⋯ We demonstrate the low thrombogenicity of the AN69ST®; dialyzer that allows post-dilution hemodiafiltration sessions without systemic anticoagulation, and without increasing the frequency of severe clotting events compared to HF80®; dialyzer with nadroparin and with less risk of bleeding by not modifying the anti-Xa factor activity.