Ultraschall in der Medizin : Organ der Deutschen Gesellschaft für Ultraschall in der Medizin, [der] Österreichischen Gesellschaft für Ultraschall in der Medizin, [der] Schweizerischen Gesellschaft für Ultraschall in Medizin und Biologie
-
In the last 12 - 18 months nearly all ultrasound manufacturers have arrived to implement ultrasound shear wave elastography modality in their equipment for the assessment of chronic liver disease; the few remaining players are expected to follow in 2016. When all manufacturers rush to a new technology at the same time, it is evident that the clinical demand for this information is of utmost value. Around 1990, there was similar demand for color Doppler ultrasound; high demand for contrast-enhanced ultrasonography was evident at the beginning of this century, and around 2010 demand increased for strain elastography. ⋯ This situation might lead to the adoption of a standard validated elastographic method as reference, but this has to be agreed-upon at an international level.. · Ultrasound elastography embedded in conventional scanners usually allows the choice of where to place the ROI within the color stiffness box and whether to confirm or exclude each single measurement when determining the final value. Thus, the operator has a greater potential to influence the final findings than with Fibroscan®, where these choices are not available. This has to be kept in mind to avoid the possibility that an operator could, even inadvertently, tend to confirm an assumption about that specific patient or to confirm the patient's expectations.. · Quality criteria for the new technologies following transient elastography are absent (depending on the manufacturer) or have not been satisfactorily defined, so that the information potentially inserted in a report cannot currently be judged for its reliability by the clinician.. (ABSTRACT TRUNCATED)
-
We evaluated the effects of ultrasound (US)-guided percutaneous radiofrequency thermal lesioning (RTL) and the impact of obesity when treating patients with recalcitrant plantar fasciitis. ⋯ US should be regarded as a useful objective tool to guide RTL and to monitor the effectiveness of treatment. US-guided percutaneous RTL for recalcitrant PF is a minimally invasive treatment option that yields satisfactory results. Therefore, it should at least be considered before using more invasive procedures. Moreover, obesity leads to delayed improvement but does not affect overall outcome after 12 months. Plantar fascial thickness was correlated with VAS and AOFAS scores.
-
To investigate the imaging features of intraductal papillary neoplasm in bile duct (IPNB) on baseline ultrasound and contrast-enhanced ultrasound (CEUS). ⋯ IPNB should be taken into consideration when intraductal mass or cystic-solid mass with bile duct dilation, or remarkable bile duct dilation without intraductal mass, are found on US. Intraductal mass length > 3.0 cm is more commonly found in malignant IPNB. CEUS might facilitate the diagnosis of IPNB by easily excluding the possibility of commonly found sludge, nonshadowing stones, or blood clots.
-
Hepatic vein pressure gradient (HVPG) is the gold standard for diagnosing clinically significant portal hypertension (CSPH). The aim of this study was to investigate-in comparison to HVPG-the ability to diagnose CSPH by liver and spleen stiffness measurements obtained by acoustic radiation force impulse (ARFI) imaging. ⋯ LSM and SSM by ARFI are noninvasive diagnostic tools that may help in diagnosing CSPH. LSM and SSM could be used as a guiding noninvasive screening tool in patients with esophageal varices requiring endoscopic evaluation.
-
Practice Guideline
EFSUMB Guidelines on Interventional Ultrasound (INVUS), Part I. General Aspects (long Version).
This is the first part of the Guidelines on Interventional Ultrasound of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) and covers all general aspects of ultrasound-guided procedures (long version).