The American journal of emergency medicine
-
Letter Case Reports
Recurrent central venous malposition caused by severe lower airway distortion.
-
Review Case Reports
Anaphylactic shock associated with intravenous thrombolytics: case report and an analysis from adverse event reporting system.
Adverse events including intracerebral hemorrhage and reperfusion arrhythmias are well known to occur with thrombolytic therapy. We report a case report of anaphylactic reaction directly attributable to intravenous (IV) recombinant tissue plasminogen activator and identify additional cases through review of the Food and Drug Administration Adverse Event Reporting System. A systematic review of Adverse Event Reporting System was performed for allergic adverse events occurring in conjunction with IV thrombolytics. ⋯ There was 1 death directly attributable to allergic reaction in a patient who received IV reteplase for MI. Although IV alteplase is identical to endogenous tissue plasminogen activator, it appears to be the most common cause of allergic reaction among currently used thrombolytics, with or without concomitant administration of angiotensin-converting enzyme inhibitors. A greater awareness among physicians may result in prompt recognition and treatment.
-
Studies investigating the relationship between blood gas tension and outcome in cardiac arrest survivors have reported conflicting results. This might have resulted from the use of a blood gas value at a single time point and the difference in the proportion of patients treated with therapeutic hypothermia (TH). We investigated the association of the mean blood gas tensions calculated from blood gas values obtained between restoration of spontaneous circulation and end of TH with the outcome in cardiac arrest patients treated with TH. ⋯ Mean Pao2 had no independent association with in-hospital mortality whereas hypocarbia was independently associated with in-hospital mortality. We also found a V-shaped independent association between the mean Pao2 and poor neurologic outcome at hospital discharge.
-
Case Reports
Aortic intramural hematoma and hepatic artery pseudoaneurysm: unusual complication following resuscitation.
We present a case of a 71-year-old woman with an unusual complication of aortic intramural hematoma and hepatic artery pseudoaneurysm following cardiopulmonary resuscitation and thrombolysis done for sudden cardiopulmonary arrest and pulmonary embolism. Patient was on Warfarin treatment for a prior history of pulmonary embolism and experienced recurrent cardiac arrests, which finally resolved after intravenous administration of thrombolytic agents. However, follow-up computed tomographic angiography revealed descending aortic intramural hematoma with intramural blood pool and concomitant liver laceration with hepatic artery pseudoaneurysm. ⋯ Although the use of thrombolytic agents in patients with pulmonary embolism and cardiac arrest is still a matter of debate, this case report supports the concept that thrombolysis has a role in restoring cardiopulmonary circulation, especially in recurrent cardiac arrests resulting from pulmonary embolism. On the other hand, this case also highlights the increased association of the bleeding-related complication as a result of vigorous efforts of cardiopulmonary resuscitation. Aggressive management with interventional radiology for hepatic pseudoaneurysm and conservative management of the aortic intramural hematoma resulted in favorable outcome for our patient.
-
Comparative Study Clinical Trial
Contrast enhanced ultrasound vs chest X-ray to determine correct central venous catheter position.
We aimed to analyze the diagnostic accuracy of contrast enhanced ultrasonography (CEUS), compared with chest x-ray (CXR), in the detection of correct central venous line (CVL) placement. Our hypothesis was to verify whether CEUS could substitute CXR as a reference standard for correct placement of CVL or function as a triage test to limit the execution of CXR only for selected patients. ⋯ CEUS can't substitute CXR, or become a triage test in selected patients, in evaluating the correct tip position after CVL placement.