The American journal of emergency medicine
-
Review Case Reports
Cannabinoid hyperemesis acute renal failure: a common sequela of cannabinoid hyperemesis syndrome.
We report the case of a 25-year-old man with an 8-year history of daily marijuana use diagnosed with acute renal failure secondary to cannabinoid hyperemesis syndrome. The patient presented with “constant” vomiting for over a day. His symptoms were completely relieved with compulsive hot showering and partially relieved by hot baths, by high ambient room temperature, and transiently after smoking marijuana. ⋯ The unique combination of intractable vomiting and constant hot showers seems to put CHS patients at significant risk of severe dehydration and prerenal failure, a common and distinct entity we suggest be termed cannabinoid hyperemesis acute renal failure (CHARF). The characteristics of cannabinoid hyperemesis acute renal failure patients were similar to CHS patients, except a larger portion were over the age of 30 (4 of 6, vs 30%). Evaluating physicians should maintain a high degree of suspicion for this common sequela of CHS.
-
We encountered a case of severe acute respiratory distress syndrome in late pregnancy due to influenza (H1N1) with refractory hypoxemia to conventional mechanical ventilation. Ventilation in prone position rescued this patient by maintaining oxygenation and sustaining improvement thereafter. ⋯ It requires frequent monitoring of possible complications due to prone position and highly dedicated supporting staffs. More data are required on safety of proning in the late pregnancy.
-
Intramedullary pressure changes during intraosseous (IO) procedures have been implicated in the intravasation of bone marrow fat and with pain in conscious patients. The objective of this study was to demonstrate inter-provider variability in pressures generated during initial flush procedures. ⋯ The IO compartment pressures generated by physicians demonstrated significant interoperator variability with greater than 35-fold difference in flush forces, and an inverse relationship between intraosseous pressure and flush duration. It may be prudent practice for providers to extend the flush over several seconds, thus limiting maximal pressures.
-
Nebulized particles must have diameters between 1 to 5 μm (optimal particle size range [OPSR]) to be deposited in the lower respiratory tract. The purpose of this study is to determine factors that affect the particle size distributions of nebulized albuterol. ⋯ Single-use disposable nebulizers do not degrade with use, but their performance is highly dependent on gas flow rates. At the flow rate achieved by the home pump, the semipermanent nebulizer performs better than the SUD nebulizer.
-
Various emergency department (ED) HIV testing models are reported in the literature but may not all be sustainable. We sought to determine whether changing an ED rapid HIV testing program from counselor-based to ED technician-based resulted in more testing. ⋯ We present a novel approach to HIV testing using existing staff within the ED. This new ED technician-based model led to large increases in rates of testing.