Intra-aortic balloon pump (IABP) counterpulsation in cardiogenic shock (CS) is suggested as bridging therapy to definite emergency revascularization, heart transplantation and acute valvular repair. Data concerning the use of IABP counterpulsation in an emergency department (ED) are rare. ⋯ Initiation of IABP counterpulsation in patients with CS in an ED appears safe. Low levels of serum lactate and younger age were independent predictors of survival. In patients with ACS PTCA may contribute to improved outcome.
-
Case Reports
Osteomyelitis at the injection site of adrenalin through an intraosseous needle in a 3-month-old infant.
Intraosseous (IO) puncture is considered for the administration of drugs and fluids when vascular access cannot be achieved rapidly. Adrenaline/epinephrine, adenosine, crystalloids, colloids and blood products can be applied and administered effectively using this route during resuscitation of children. This technique is relatively simple with complications of <1%. ⋯ Radiologically, no osseous lesion could be demonstrated, however, a bone scintigram revealed osteomyelitis. Upon surgical revision, purulent destruction was evident requiring removal of the epiphysis and part of the metaphysis. Although osteomyelitis is a rare complication which may be caused by sepsis, or contamination during insertion, we speculate that adrenaline in high concentrations may promote the development of osteomyelitis and the drug should be applied cautiously in more diluted concentrations.
-
We studied the performance of external chest compression by 20 fourth year medical students on 2 study days, separated by 5-7 weeks, 4-8 months after they had been initially trained in cardiopulmonary resuscitation (CPR). Our hypotheses were (1) that a given individual would perform external chest compressions in the same manner each time CPR was performed and (2) that the pattern of performance of chest compressions would be determined, in part, by the anthropometric characteristics of the rescuer. A Laerdal Skillmeter Resusci-Anne CPR manikin chest compression transducer was interfaced with an analogue-to-digital conversion board in a Macintosh LC III computer. ⋯ In addition, we calculated the regression slope of compression depth versus compression number for each cycle of 15 chest compressions and over four cycles of compressions. Statistically significant correlations were observed between the first and second study days in each of the variables of chest compression measured, indicating that the performance of chest compressions was constant over time for a given individual. We observed that the depth of compression, duty cycle, time to peak compression, time to peak velocity and regression slope of depth of compressions versus compression number were significantly related to the height and weight of the rescuer.