Journal of vascular surgery
-
Comparative Study
Comparison of indirect radiation dose estimates with directly measured radiation dose for patients and operators during complex endovascular procedures.
A great deal of attention has been directed at the necessity and potential for deleterious outcomes as a result of radiation exposure during diagnostic evaluations and interventional procedures. We embarked on this study in an attempt to accurately determine the amount of radiation exposure given to patients undergoing complex endovascular aortic repair. These measured doses were then correlated with radiation dose estimates provided by the imaging equipment manufacturers that are typically used for documentation and analysis of radiation-induced risk. ⋯ FT cannot be used to estimate PSD, and CAK and KAP represent poor surrogate markers for JCAHO-defined sentinel events. Even when directly measured PSDs were used, there was a poor correlation with clinical event (no skin injuries with an average PSD >2 Gy). The effective radiation dose of an eTAAA is equivalent to two preoperative computed tomography scans. The maximal operator exposure is 50 mSv/year, thus, a single operator could perform up to 294 eTAAA procedures annually before reaching the recommended maximum operator dose.
-
Pathologic studies have demonstrated that aortic dissection is initiated by an intimal tear, followed by the rapid growth of an intramural hematoma that dissects the media and is characterized by elastin degradation. Genetic extracellular matrix abnormalities and proteinases may be the predisposing factors in aortic dissection, but little is known about the role of elastic fiber assembly. Fibulin-1 is an extracellular protein that is expressed in the vascular basement membrane. It regulates elastic fiber assembly and hence provides integrity in aortic structure. This study investigates the expression profiles of genes responsible for the elastolysis in the dissected human aorta, especially those coding fibulin-1, matrix metalloproteinase-9 (MMP-9), and elastin. ⋯ Our gender- and age-matched study demonstrated that the alternated genes in the elastin assembly of dissected aortas may predispose structural failure in the aorta leading to dissection. However, no significant gene alterations in the adjacent intact and dissected aortas of the same patient can be found. Therefore, the genetic changes found in the dissected aortas most likely developed before the dissection starts. The inhibition of the aberrant expression of the fibulin-1 gene and that of the related matrix proteinase may open a new avenue for preventing aortic dissection.
-
Endovascular repair for complex thoracic aortic pathology has emerged over the past decade as an alternative to open surgical repair. Reports suggest lower morbidity and mortality rates associated with endovascular interventions. The purpose of this report was to analyze a large single institution experience in endovascular thoracic aortic repair based on clinical presentation as well as within and outside specific instructions for use. ⋯ Results of this single-institution report suggest that endovascular thoracic aortic repair is a safe and effective treatment option for a variety of thoracic pathology including both elective and emergent cases. However, off-label usage of the devices is associated with a significantly higher risk of mortality and spinal cord ischemia, but the risk still appears acceptable given the majority of cases were emergent.
-
Venous bullet embolism is a rare and complicated occurrence reported in approximately 0.3% of penetrating trauma. The management of bullet emboli is decided on a case-by-case basis, balancing the risk of the embolus itself against those associated with extraction. We report a case of a 19-year-old man who sustained a gunshot wound to the anterior chest, which migrated to the left internal iliac vein in a retrograde fashion. We were able to successfully retrieve the missile using an endovascular approach, thereby minimizing the morbidity associated with an open procedure.
-
The Vascular Surgery Board (VSB) of the American Board of Surgery sought to answer the following questions: what is the scope of contemporary vascular surgery practice? Do current vascular surgery residents obtain training that is appropriate for their future career expectations and for successful Board certification? How effectively do practicing vascular surgeons incorporate emerging technologies and procedures into practice? ⋯ Over the past 15 years, there has been a significant increase in the total number of operative cases reported to the VSB by both QE and RE applicants. Contrary to popular belief, the volume of major open vascular surgery reported by recent vascular surgery residents has remained relatively stable since 1994. Over the same time period, endovascular procedures have been rapidly incorporated into clinical practice by the majority of vascular surgeons applying for recertification by the VSB. Current vascular surgery residents receive a rich operative experience in both open and endovascular procedures that is reflective of contemporary practice.