European journal of anaesthesiology
-
Local anaesthesia combined with conscious sedation is becoming a popular technique for implantation of cardioverter-defibrillator devices. Propofol was given to provide loss of consciousness during defibrillation shock administration, for induced ventricular fibrillation testing. Propofol was found to decrease QT interval and QT dispersion in two patients with idiopathic prolonged QT interval and QT dispersion. The findings of the procedure are reported.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Efficacy and side effects of tramadol versus oxycodone for patient-controlled analgesia after maxillofacial surgery.
Tramadol, a weak opioid mu-receptor agonist, may have a favourable potency and side effect profile for intravenous patient-controlled analgesia (PCA). In a prospective, double-blind, randomized study involving 54 patients, tramadol was compared with oxycodone in PCA after maxillofacial surgery. All the patients were given diclofenac sodium 1 mg kg-1 intramuscularly and dexamethasone 8 mg twice a day. ⋯ No respiratory depression was identified. Tramadol was found to provide adequate analgesia after maxillofacial surgery without risk of respiratory depression. However, the incidence of nausea was slightly greater in the tramadol group than in the oxycodone group (44% vs. 28%, NS).
-
Randomized Controlled Trial Comparative Study Clinical Trial
Patient-controlled epidural analgesia with morphine or morphine plus ketamine for post-operative pain relief.
Sixty patients were randomly assigned to two equal groups. Group I received epidural morphine 1 mg after surgery and used a patient-controlled analgesia device programmed to deliver morphine 0. 2 mg h-1, 0.2 mg per bolus. Group II received an epidural loading dose of morphine 1 mg plus ketamine 5 mg and used a patient-controlled analgesia device programmed to deliver morphine 0. 2 mg+ketamine 0.5 mg h-1, morphine 0.2 mg+ketamine 0.5 mg per bolus with a lockout time of 10 min. ⋯ Vomiting occurred more frequently in group I (26%) than in group II (13%). The frequency and severity of pruritus and level of sedation were similar in the two groups. These findings suggest that patient-controlled epidural analgesia with morphine plus ketamine may provide effective analgesia with a lesser dose of morphine and fewer subsequent side effects, compared with patient-controlled epidural analgesia with morphine alone after lower abdominal surgery.
-
Randomized Controlled Trial Comparative Study Clinical Trial
Anaesthesia for ultrasound guided oocyte retrieval: midazolam/remifentanil versus propofol/fentanyl regimens.
To evaluate the quality of intra-operative anaesthesia and recovery characteristics of two different anaesthesia regimens, 60 healthy women undergoing ultrasound guided oocyte retrieval for in vitro fertilization procedures were randomly allocated to receive either a propofol/fentanyl or a midazolam/remifentanil based anaesthesia. The surgical procedure was successful in all patients and no severe side effects were reported by any patient. ⋯ The time to achieve an Aldrete's score of 10 was shorter in the midazolam/remifentanil patients (2 +/- 2 min) than in those who received propofol/fentanyl (4 +/- 2 min) (P < 0.001), but no differences were observed in the time required to be 'fit to discharge' from the post-anaesthesia care unit. We conclude that the use of a midazolam/remifentanil regimen is as effective and safe as a fentanyl/propofol regimen in patients undergoing transvaginal oocyte retrieval for in vitro fertilization procedures.
-
Randomized Controlled Trial Clinical Trial
The effects of nitrous oxide and ketamine on the bispectral index and 95% spectral edge frequency during propofol-fentanyl anaesthesia.
In this study, we have sought to establish whether N2O and ketamine alter the bispectral index during propofol-fentanyl anaesthesia. Fourteen surgical patients were randomly assigned to one of two groups: the N2O group (n = 7) and the ketamine group (n = 7). In both groups, anaesthesia was induced with propofol 1.5-2 mg kg-1 and fentanyl 2 micrograms kg-1 and maintained with propofol 5-7 mg kg-1 hr-1 to target the bispectral index between 40 and 50. ⋯ The bispectral index and 95% spectral edge frequency did not change significantly in the N2O group, but increased significantly from 44.1 +/- 0.7 and 16.0 +/- 0.5 to 58.6 +/- 1.4 and 19.5 +/- 0.3 (P < 0.01), respectively, in the ketamine group. Additional N2O or ketamine did not decrease the bispectral index and 95% spectral edge frequency values. The depth of sedation should be assessed carefully using a bispectral index monitor when these anaesthetic agents are used together.