Der Unfallchirurg
-
Review Case Reports
[Bent titanium elastic nail in clavicular non-union : Case report and review of the literature.]
Fractures of the clavicle can often be treated conservatively. For severely dislocated but simple fractures in which conservative treatment often fails, intramedullary nailing with titanium elastic nails (TEN) shows similar results to stable plate osteosynthesis. We present the case of a 28-year-old female patient who had been treated with TEN osteosynthesis 4 years previously but clavicular non-union developed. ⋯ We were able to remove the wire and stable plate osteosynthesis was carried out. Bending and migration of titanium wires used in clavicular fractures are relatively rare complications and patients must be informed accordingly. These complications can be avoided by removal of the wire 3-12 months after implantation when the fracture has healed.
-
Complications related to arthrodesis of the ankle or total ankle replacement require a critical assessment of the indication. Using denervation of the ankle, we have the possibility to delay the above-named surgical treatment for a number of years. The aim of this follow-up study was to review the results of ankle denervation after several years. ⋯ Ankle denervation can achieve good ankle pain reduction in the treatment of ankle arthrosis. Denervation should be considered a long-term treatment concept.