Current implementations of coronary artery magnetic resonance angiography (MRA) suffer from limited coverage of the coronary arterial system. Whole-heart coronary MRA was implemented based on a free-breathing steady-state free-precession (SSFP) technique with magnetization preparation. The technique was compared to a similar implementation of conventional, thin-slab coronary MRA in 12 normal volunteers. ⋯ Whole-heart coronary MRA visualized LM/LAD (11.7 +/- 3.4 cm) and LCX (6.9 +/- 3.6 cm) over a significantly longer distance than the transverse volume (LM/LAD, 6.1 +/- 1.1 cm, P < 0.001; LCX, 4.2 +/- 1.2 cm, P < 0.05). Improvements in visible vessel length for RCA and LCX in the whole-heart approach vs. their respective targeted volumes were not significant. It is concluded that the whole-heart coronary MRA technique improves visible vessel length and facilitates high-quality coronary MRA of the complete coronary artery tree in a single measurement.
-
Spiral imaging has recently gained acceptance in MR applications requiring rapid data acquisition. One of the main disadvantages of spiral imaging, however, is blurring artifacts that result from off-resonance effects. Spatial-spectral (SPSP) pulses are commonly used to suppress those spins that are chemically shifted from water and lead to off-resonance artifacts. ⋯ In the spiral three-point Dixon technique, water-fat signal decomposition and image deblurring are performed based on the frequency maps that are directly derived from the acquired images. In the spiral two-point Dixon technique, several predetermined frequencies are tested to create a frequency map. The newly proposed techniques can achieve more effective and more uniform fat signal suppression when compared to the conventional spiral acquisition method with SPSP pulses.
-
One primary disadvantage of spiral imaging is blurring artifact due to off-resonance effects. The conventional frequency segmented off-resonance correction method that is performed over the entire image is computationally intense due to the large number of fast Fourier transforms (FFTs) required. Here, a new fast off-resonance correction method, block regional off-resonance correction (BRORC), is presented. ⋯ The BRORC algorithm is typically several times more computationally efficient than the conventional off-resonance correction algorithm. Additional computational reductions can be expected for the BRORC if only specific image regions require deblurring. The newly proposed off-resonance correction method offers significant speed advantages and equivalent image quality when compared to conventional off-resonance correction methods.
-
Various pulse sequences for fast proton spectroscopic imaging (SI) using the steady-state free precession (SSFP) condition are proposed. The sequences use either only the FID-like signal S(1), only the echo-like signal S(2), or both signals in separate but adjacent acquisition windows. As in SSFP imaging, S(1) and S(2) are separated by spoiler gradients. ⋯ The methods are of particular interest at higher magnetic field strength B(0), as TR can be reduced with increasing B(0) leading to a reduced T(min) and an increased SNR(t). Drawbacks consist of the limited spectral resolution, particularly at lower B(0), and the dependence of the signal intensities on T(1) and T(2). Further improvements are discussed including optimized data processing and signal detection under oscillating B(0) gradients leading to a further reduction in T(min).
-
It has been shown that quantitative MRI thermometry using the proton resonance frequency (PRF) method can be used to noninvasively monitor the evolution of tissue temperature, and to guide minimally-invasive tumor ablation based on local hyperthermia. Although hepatic tumors are among the main targets for thermal ablation, PRF-based temperature MRI of the liver is difficult to perform because of motion artifacts, fat content, and low T(*) (2). In this study the stability of real-time thermometry was tested on a clinical 1.5 T scanner for rabbit liver in vivo. ⋯ The method was used to guide thermal ablation experiments with a clinical infrared laser. The estimated size of the necrotic area, based on the thermal dose calculated from MR temperature maps, corresponded well with the actual lesion size determined by histology and conventional MR images obtained 5 days posttreatment. These results show that quantitative MR temperature mapping can be obtained in the liver in vivo, and can be used for real-time control of thermal ablation and for lesion size prediction.