Magnetic resonance in medicine : official journal of the Society of Magnetic Resonance in Medicine
-
Although three-dimensional (3D) turbo spin echo (TSE) with variable flip angles has proven to be useful for intracranial vessel wall imaging, it is associated with inadequate suppression of cerebrospinal fluid (CSF) signals and limited spatial coverage at 3 Tesla (T). This work aimed to modify the sequence and develop a protocol to achieve whole-brain, CSF-attenuated T1 -weighted vessel wall imaging. ⋯ The new 3D TSE sequence allows for high-quality T1 -weighted intracranial vessel wall imaging at 3 T. It may potentially aid in depicting small arteries and revealing T1 -mediated high-signal wall abnormalities. Magn Reson Med 77:1142-1150, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
-
Comparative Study
Fitting methods for intravoxel incoherent motion imaging of prostate cancer on region of interest level: Repeatability and gleason score prediction.
To evaluate different fitting methods for intravoxel incoherent motion (IVIM) imaging of prostate cancer in the terms of repeatability and Gleason score prediction. ⋯ Monoexponential model demonstrated the highest repeatability and clinical values in the regions-of-interest based analysis of prostate cancer DWI, b-values in the range of 0-500 s/mm2 . Magn Reson Med 77:1249-1264, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
-
To implement pulmonary three-dimensional (3D) radial ultrashort echo-time (UTE) MRI in non-sedated, free-breathing neonates and adults with retrospective motion tracking of respiratory and intermittent bulk motion, to obtain diagnostic-quality, respiratory-gated images. ⋯ Three-dimensional radial pulmonary UTE MRI allows for retrospective respiratory self-gating and removal of intermittent bulk motion in free-breathing, non-sedated neonates and adults. Magn Reson Med 77:1284-1295, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
-
To propose a novel reconstruction method using parallel imaging with low rank constraint to accelerate high resolution multishot spiral diffusion imaging. ⋯ Robust high resolution diffusion weighted image can be efficiently reconstructed from highly undersampled multishot spiral data with the proposed LR-SENSE method. Magn Reson Med 77:1359-1366, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
-
To develop a flexible fast spin echo (FSE) triple-echo Dixon (FTED) technique. ⋯ The flexible FTED technique incorporates the benefits of both FSE and Dixon imaging and provided more flexibility than the original FTED in applications such as fat-suppressed T2-weighted and T1-weighted imaging. Magn Reson Med 77:1049-1057, 2017. © 2016 International Society for Magnetic Resonance in Medicine.