The combination of parallel imaging with partial Fourier acquisition has greatly improved the performance of diffusion-weighted single-shot EPI and is the preferred method for acquisitions at low to medium magnetic field strength such as 1.5 or 3 T. Increased off-resonance effects and reduced transverse relaxation times at 7 T, however, generate more significant artifacts than at lower magnetic field strength and limit data acquisition. Additional acceleration of k-space traversal using a multishot approach, which acquires a subset of k-space data after each excitation, reduces these artifacts relative to conventional single-shot acquisitions. ⋯ The reconstruction uses a simple modification of the standard sensitivity-encoding (SENSE) algorithm to account for shot-to-shot phase errors; the method is called image reconstruction using image-space sampling function (IRIS). Using this approach, reconstruction from highly aliased in vivo image data using 2-D navigator phase information is demonstrated for human diffusion-weighted imaging studies at 7 T. The final reconstructed images show submillimeter in-plane resolution with no ghosts and much reduced blurring and off-resonance artifacts.
-
Velocity-selective (VS) arterial spin labeling is a promising method for measuring perfusion in areas of slow or collateral flow by eliminating the bolus arrival delay associated with other spin labeling techniques. However, B(0) and B(1) inhomogeneities and eddy currents during the VS preparation hinder accurate quantification of perfusion with VS arterial spin labeling. ⋯ A novel eight-segment B(1) insensitive rotation VS preparation is proposed to reduce eddy current effects while maintaining the B(0) and B(1) insensitivity of previous preparations. Compared to two previous VS preparations, the eight-segment B(1) insensitive rotation is the most robust to eddy currents and should improve the quality and reliability of VS arterial spin labeling measurements in future studies.
-
Reaching the full potential of magnetic resonance imaging (MRI)-positron emission tomography (PET) dual modality systems requires new methodologies in quantitative image analyses. In this study, methods are proposed to convert an arterial input function (AIF) derived from gadolinium-diethylenetriaminepentaacetic acid (Gd-DTPA) in MRI, into a (18)F-fluorodeoxyglucose ((18)F-FDG) AIF in PET, and vice versa. The AIFs from both modalities were obtained from manual blood sampling in a F98-Fisher glioblastoma rat model. ⋯ Pharmacokinetic MRI parameters such as the volume transfer constant (K(trans)), the extravascular-extracellular volume fraction (ν(e)), and the blood volume fraction (ν(p)) calculated with the Gd-DTPA AIF and the Gd-DTPA AIF converted from (18)F-FDG AIF normalized with or without blood sample were not statistically different. Similarly, the tumor metabolic rates of glucose (TMRGlc) calculated with (18) F-FDG AIF and with (18) F-FDG AIF obtained from Gd-DTPA AIF were also found not statistically different. In conclusion, only one accurate AIF would be needed for dual MRI-PET pharmacokinetic modeling in small animal models.
-
Most experiments assume a global transit delay time with blood flowing from the tagging region to the imaging slice in plug flow without any dispersion of the magnetization. However, because of cardiac pulsation, nonuniform cross-sectional flow profile, and complex vessel networks, the transit delay time is not a single value but follows a distribution. In this study, we explored the regional effects of magnetization dispersion on quantitative perfusion imaging for varying transit times within a very large interval from the direct comparison of pulsed, pseudo-continuous, and dual-coil continuous arterial spin labeling encoding schemes. Longer distances between tagging and imaging region typically used for continuous tagging schemes enhance the regional bias on the quantitative cerebral blood flow measurement causing an underestimation up to 37% when plug flow is assumed as in the standard model.
-
A simultaneous noncontrast angiography and intraplaque hemorrhage (SNAP) MR imaging technique is proposed to detect both luminal stenosis and hemorrhage in atherosclerosis patients in a single scan. Thirteen patients with diagnosed carotid atherosclerotic plaque were admitted after informed consent. All scans were performed on a 3T MR imaging system with SNAP, 2D time-of-flight and magnetization-prepared 3D rapid acquisition gradient echo sequences. ⋯ Quantitatively, the lumen size measurements by SNAP were strongly correlated (intraclass correlation coefficient = 0.96, P < 0.001) with those measured by time-of-flight. For intraplaque hemorrhage detection, strong agreement (κ = 0.82, P < 0.001) was also identified between SNAP and magnetization-prepared 3D rapid acquisition gradient echo images. In conclusion, a SNAP imaging technique was proposed and shows great promise for imaging both lumen size and carotid intraplaque hemorrhage with a single scan.