Anaesthesia and intensive care
-
Anaesth Intensive Care · Apr 2004
Comparative StudyThe type of carbon dioxide absorbent has no relation to the concentration of carbon monoxide in the breathing circuit during low-flow isoflurane anaesthesia in smoking and non-smoking subjects.
The present study was designed to investigate the concentrations of carbon monoxide (CO) in the anaesthetic circuit and of arterial carboxyhaemoglobin (COHb) during low-flow isoflurane anaesthesia in smoking and non-smoking subjects using three kinds of cardon dioxide (CO2) absorbent. Thirty smoking and 30 non-smoking subjects were selected for this study, and these two groups were each divided into three groups according to the type of CO2 absorbent used (Wakolime A, Drägersorb Free, and Amsorb). Anaesthesia was maintained with 1.0% isoflurane and nitrous oxide (1. 0 l min(-1))/oxygen (1.0 l min(-1)). ⋯ There was a significant linear correlation between the concentrations of CO and COHb (r=0.86, n =30, P<0.001). In the non-smoking groups all of the parameters remained constant at low levels that were independent of the type of CO2 absorbents tested. The major source for increased intraoperative CO exposure is related to the patient's smoking status, and the type of CO2 absorbent used has no relation to an increase in CO concentration in the breathing circuit.
-
Anaesth Intensive Care · Apr 2004
Randomized Controlled Trial Clinical TrialSevoflurane versus propofol for induction of anaesthesia for electroconvulsive therapy: a randomized crossover trial.
Propofol is often used to induce anaesthesia for electroconvulsive therapy. Some patients who receive propofol have fits of poor quality or inadequate duration despite increasing electroconvulsive therapy doses. Sevoflurane has been reported to exhibit pro-convulsant properties in some "at-risk" patients during anaesthesia for other procedures. ⋯ Patients in both treatment groups exhibited equally good fits, with those in the sevoflurane group having slightly better morphology, which is the most subjective of the parameters measured. The sevoflurane administrations were associated with slightly higher pulse rates and blood pressures. Sevoflurane provides a suitable alternative to propofol for anaesthesia in patients undergoing electroconvulsive therapy, although the slightly greater pulse rate rise and blood pressure rise should be considered in patients with ischaemic heart disease.
-
Anaesth Intensive Care · Apr 2004
Comparative StudyComparison of propofol consumption and recovery time in Caucasians from Italy, with Chinese, Malays and Indians from Malaysia.
Differences in sensitivity to anaesthetic drugs may exist among different ethnic groups. Allelic variants for drug metabolizing isoenzymes and pharmacokinetic differences may account for a variable response to some anaesthetic drugs. This study was designed to compare propofol consumption and recovery characteristics in four ethnic groups: Chinese, Malays, and Indians in Malaysia and Caucasians in Italy. ⋯ The recovery of Indians was much slower compared to Chinese, Malays and Caucasians. The recovery time of Malays is significantly slower compared to Chinese and Caucasians. Differences in propofol consumption and recovery time were not significant between Chinese and Caucasians, but the ratio recovery time/propofol consumption was significantly lower in Caucasians compared to all the other groups.
-
Anaesth Intensive Care · Apr 2004
Clinical TrialCorrelation between extravascular lung water and oxygenation in ALI/ARDS patients in septic shock: possible role in the development of atelectasis?
This study aimed to evaluate the relationship between PaO2/FiO2 ratio and extravascular lung water in septic shock-induced acute respiratory distress syndrome in a prospective observational clinical trial. Twenty-three patients suffering from sepsis induced acute respiratory distress syndrome were recruited. All patients were ventilated in pressure control/support mode. ⋯ A post-hoc analysis was performed when "low" PEEP: < 10 cmH2O and "high" PEEP: (10 cmH2O PEEP was applied, and neither the oxygenation, nor the driving pressure or the PaCO2 differed significantly, but the extravascular lung water showed significant difference when "high" or "low" PEEP was applied (13+/-5 vs 9+/-2 ml/kg respectively, P=0.001). This study found significant negative correlation between extravascular lung water and PaO2/FiO2. The mechanism by which extravascular lung water affects oxygenation is unknown but the significant positive correlation between PEEP and extravascular lung water shown in this trial suggests that the latter may have a role in the development of alveolar atelectasis.