Anaesthesia and intensive care
-
Anaesth Intensive Care · Nov 2016
Defining a reference range for vital signs in healthy term pregnant women undergoing caesarean section.
Early warning systems (EWS), used to identify deteriorating hospitalised patients, are based on measurement of vital signs. When the patients are pregnant, most EWS still use non-pregnant reference ranges of vital signs to determine trigger thresholds. There are no published reference ranges for all vital signs in pregnancy. ⋯ This study defined a reference range for vital signs in healthy term pregnant women undergoing CS. Study findings suggest that currently used criteria for EWS triggers, based on non-pregnant values, may be too extreme for timely detection of deteriorating pregnant patients. Further research examining the modified HR triggers of ≤50 and ≥110 /minute in pregnant women and their relationship to clinical outcomes is required.
-
Anaesth Intensive Care · Nov 2016
ReviewCurrent limitations of the assessment of haemostasis in adult extracorporeal membrane oxygenation patients and the role of point-of-care testing.
Haemostatic perturbations are commonly seen in extracorporeal membrane oxygenation (ECMO) patients and remain a clinical challenge, contributing significantly to morbidity and mortality. The approach to anticoagulation monitoring and the management of bleeding varies considerably across ECMO centres. Routine laboratory tests have their limitations in terms of turnaround time and specificity of information provided. ⋯ It is also possible to obtain qualitative information on platelet function from these tests. Furthermore, the ability to incorporate these results into a goal-directed algorithm to manage bleeding with targeted transfusion strategies appears particularly attractive and cost effective. Further studies are required to evaluate the utility of POCT to optimise bleeding and anticoagulation management in these complex patients.
-
Anaesth Intensive Care · Nov 2016
Randomized Controlled TrialDriving impairment due to propofol at effect-site concentrations relevant after short propofol-only sedation.
Australian guidelines state "Following brief surgery or procedures with short acting anaesthetic drugs, the patient may be fit to drive after a normal night's sleep. After long surgery or procedures requiring longer lasting anaesthesia, it may not be safe to drive for 24 hours or more". The increasing use of the short-acting anaesthetic drug propofol as a solitary sedative medication for simple endoscopy procedures suggests a need to review this blanket policy. ⋯ Driving impairment at 0.2 µg/ml propofol effect-site concentration was not statistically different to placebo. Impairment increased with propofol effect-site concentration (P=0.002) and at 0.4 µg/ml it was similar to that found with a blood alcohol concentration of 50 mg/100 ml (0.05%). Plasma propofol concentrations of 0.2 µg/ml, as might be found approximately an hour after short (<1 hour duration) propofol-only sedation for endoscopy, were not associated with driving impairment in our young cohort of volunteers.
-
Anaesth Intensive Care · Nov 2016
Comparative StudyA comparative study of tracheal diameter in Caucasian and Chinese patients.
Ethnicity may be considered a factor when considering what size endotracheal tube to insert. In particular it has been suggested that Chinese patients have a smaller tracheal diameter, justifying the selection of smaller endotracheal tubes. We systematically evaluated transverse tracheal diameters in Chinese and Caucasian patients, utilising archived computer tomography images. ⋯ Multivariate analysis demonstrated only a small influence related to ethnicity (12% relative contribution to the overall variance [R2] of the model), but substantial influence of height (40%) and sex (41%). Our findings do not support the practice of routinely selecting a smaller endotracheal tube size for Chinese patients on the basis that there is a difference related to the Chinese ethnic phenotype. Considerations regarding choice of endotracheal tube size should rather focus on patient sex and height.
-
Anaesth Intensive Care · Nov 2016
Can femoral venous pressure be used as an estimate for standard vesical intra-abdominal pressure measurement?
Intra-abdominal hypertension (IAH) is highly prevalent in critically ill patients admitted to the intensive care unit and is associated with an increased morbidity and mortality. The present study investigated whether femoral venous pressure (FVP) can be used as a surrogate parameter for intra-abdominal pressure (IAP) measured via the bladder in IAH grade II (IAP <20 mmHg) or grade III (IAP ≥20 mmHg). This was a single-centre prospective study carried out in a tertiary adult intensive care unit. ⋯ A receiver operating characteristic analysis for FVP to predict IAH showed an area under the curve of 0.87 (95% confidence interval 0.74-0.94, P=0.0001). FVP cannot be recommended as a surrogate measure for IAP even at IAP values above 20 mmHg. However, an elevated FVP was a good predictor of IAH.