Anaesthesia and intensive care
-
Anaesth Intensive Care · Jan 2021
Meta AnalysisSafety and efficacy of routine diagnostic test reduction interventions in patients admitted to the intensive care unit: A systematic review and meta-analysis.
Reducing unnecessary routine diagnostic testing has been identified as a strategy to curb wasteful healthcare. However, the safety and efficacy of targeted diagnostic testing strategies are uncertain. The aim of this study was to systematically review interventions designed to reduce pathology and chest radiograph testing in patients admitted to the intensive care unit (ICU). ⋯ Of the 18 studies reporting a difference in testing rates, all reported a decrease associated with targeted testing (range 6%-72%), with 14 (82%) studies reporting >20% reduction in one or more tests. Studies of ICU targeted test interventions are generally of low quality. The majority report substantial decreases in testing without evidence of a significant difference in hospital mortality.
-
Anaesth Intensive Care · Sep 2017
Review Meta AnalysisEffect of nicotine replacement therapy on mortality, delirium, and duration of therapy in critically ill smokers: a systematic review and meta-analysis.
Nicotine replacement therapy is widely used in critically ill smokers and its effect on delirium, mortality and duration of intensive care unit (ICU) admission is unknown. The aims of this review were to determine whether the management of nicotine withdrawal with nicotine replacement therapy reduces delirium, mortality or length of stay in critically ill smokers in ICU. The primary outcome was incidence of author-defined ICU delirium. ⋯ In a meta-analysis of observational studies, nicotine replacement therapy was associated with increased delirium (three studies; n=908; I2=0%; finite element method: odds ratio 4.03 [95% confidence interval 2.64, 6.15]; P <0.001). There was no difference in ICU mortality (three studies; n=1,309; P=0.10, I2=44%; finite element method: odds ratio 0.58; 95% confidence intervals 0.31-1.10) and hospital mortality or 28-day ICU-free days. In the absence of high-quality data, nicotine replacement therapy cannot currently be recommended for routine use to prevent delirium or to reduce hospital or ICU mortality in critically ill smokers.
-
Anaesth Intensive Care · Jan 2017
Review Meta AnalysisApnoeic oxygenation during intubation: a systematic review and meta-analysis.
Apnoeic oxygenation during intubation is used to prevent desaturation during intubation. The aim of this review was to assess whether apnoeic oxygenation during endotracheal intubation reduced the incidence of hypoxaemia. Five major databases were systematically searched for all relevant studies published up to May 2016. ⋯ This is the first meta-analysis to be performed on apnoeic oxygenation during intubation. Apnoeic oxygenation provides significant benefit in terms of improving SpO2 for the majority of intubations, although there appears to be no benefit in patients whose indication for intubation is respiratory failure. Apnoeic oxygenation ought to be considered for integration into intubation protocols.
-
Anaesth Intensive Care · Sep 2016
Review Meta AnalysisDoes objective measurement of tracheal tube cuff pressures minimise adverse effects and maintain accurate cuff pressures? A systematic review and meta-analysis.
Correct inflation pressures of the tracheal cuff are recommended to ensure adequate ventilation and prevent aspiration and adverse events. However there are conflicting views on which measurement to employ. The aim of this review was to examine whether adjustment of cuff pressure guided by objective measurement, compared with subjective measurement or observation of the pressure value alone, was able to prevent patient-related adverse effects and maintain accurate cuff pressures. ⋯ These included cough at two hours (odds ratio [OR] 0.42, confidence interval [CI] 0.23 to 0.79, P=0.007), hoarseness at 24 hours (OR 0.49, CI 0.31 to 0.76, P <0.002), sore throat (OR 0.73, CI 0.54 to 0.97, P <0.03), lesions of the trachea and incidences of silent aspiration (P=0.001), as well as maintaining accurate cuff pressures (Hedges' g 1.61, CI 2.69 to 0.53, P=0.003). Subjective measurement to guide adjustment or observation of the pressure value alone may lead to patient-related adverse effects and inaccuracies. It is recommended that an objective form of measurement be used.