Anaesthesia and intensive care
-
The laryngeal mask airway, the LMA® Gastro™ (Teleflex Medical, Athlone, Ireland), is a novel airway device which permits upper gastrointestinal (GI) endoscopy to be performed via a dedicated large calibre oesophageal lumen. It has been validated in adult studies, but to our knowledge, there have been no data published regarding its use in a paediatric population. Following a brief education programme, the LMA Gastro was introduced on a trial basis at our institution and made freely available. ⋯ First-pass oesophageal access was achieved in 51 (98%) cases, and 100% of insertions were rated 'easy' by the gastroenterologist. Despite our relative inexperience with it, the device had a high success rate for airway maintenance and oesophageal access in our paediatric patient population. In our institution, the LMA Gastro provided a useful airway option in older children undergoing elective upper GI endoscopy.
-
Anaesth Intensive Care · Mar 2021
Intensive care digital health response to emerging infectious disease outbreaks such as COVID-19.
The COVID-19 pandemic has required intensive care units to rapidly adjust and adapt their existing practices. Although there has a focus on expanding critical care infrastructure, equipment and workforce, plans have not emphasised the need to increase digital capabilities. ⋯ We identified and explored six focus areas relevant to intensive care, including using digital solutions to increase critical care capacity, developing surge capacity within an electronic health record, maintenance and downtime planning, training considerations and the role of data analytics. This article forms the basis of a framework for the intensive care digital health response to COVID-19 and other emerging infectious disease outbreaks.
-
Anaesth Intensive Care · Mar 2021
Randomized Controlled TrialA randomised crossover study to compare the user seal check and quantitative fit test between two types of duckbill N95 particulate respirator masks: The Halyard Fluidshield® N95 and the BSN Medical ProShield® N-95 particulate respirator masks.
N95 particulate respirator masks are currently recommended for all healthcare workers who care for patients with suspected or confirmed coronavirus disease (COVID-19) when performing aerosol-generating procedures. The protection provided by N95 particulate respirator masks is dependent on the filter's efficiency and seal quality. In this prospective randomised crossover study, we conducted the user seal check and the quantitative fit test on two readily available duckbill models of N95 masks, the Halyard Fluidshield® N95 (Halyard, Alpharetta, GA, USA) and the BSN Medical ProShield® N-95 (BSN Medical, Mount Waverley, Victoria) particulate respirator masks. ⋯ We found that both types of masks provided reasonably high fit test pass rates among our participants and there was no significant difference between the two brands (77% for the Fluidshield and 65% for the ProShield, P = 0.916). Ninety-two percent of the participants could find at least one well-fitted mask among these two types of masks. We also demonstrated that the user seal check had low accuracy and low concordance (kappa coefficient of 0.16 for the Fluidshield and 0.08 for the ProShield) when compared to the quantitative fit test, and hence was not a reliable method to test seal quality.