Critical care clinics
-
Critical care clinics · Jul 2018
ReviewComplications of Durable Left Ventricular Assist Device Therapy.
Heart failure patients on durable left ventricular assist device support experience improved survival, quality of life, and exercise capacity. The complication rate, however, remains unacceptably high, although it has declined with improvements in pump design, better patient selection, and greater understanding of the pump physiology and flow dynamics. Most complications are categorized as those related to the pump-patient interface or those related to patient physiology. It is hoped that further engineering progress, and better patient selection through risk stratification, will allow for left ventricular assist device to be totally biocompatible and perform effectively, without affecting biology and homeostasis of the different organ systems.
-
Poor synchrony between the delivery of mechanical breaths, the neural respiratory timing, and needs of patients is relatively frequent under mechanical ventilation in the intensive care unit. This review summarizes the current knowledge on the different types of dyssynchrony described to date, their mechanism, consequences, and potential management. There is still a long way to get to a comprehensive knowledge and uncertainties remain. Ongoing research and development of monitoring tools are urgently needed to allow a better appraisal of this area in a near future.
-
Noninvasive ventilation (NIV) has assumed a central role in the treatment of selected patients with acute respiratory failure due to exacerbated chronic obstructive pulmonary disease or acute cardiogenic pulmonary edema. Recent advances in the understanding of physiologic aspects of NIV application through different interfaces and ventilator settings have led to improved patient-machine interaction, enhancing favorable NIV outcome. In recent years, the growing role of NIV in the acute care setting has led to the development of technical innovations to overcome the problems related to gas leakage and dead space, improving the quality of the devices and optimizing ventilation modes.
-
Extracorporeal gas exchange is increasingly used for various indications. Among these are refractory acute respiratory failure, including the acute respiratory distress syndrome (ARDS), and the avoidance of ventilator-induced lung injury (VILI) by enabling lung-protective ventilation. ⋯ These indications are based on a reasonable physiologic rationale but must be weighed against the costs and complications associated with the technique. This article summarizes current evidence and indications for extracorporeal gas exchange.
-
Critical care clinics · Jul 2018
ReviewDeterminants and Prevention of Ventilator-Induced Lung Injury.
Ventilator-induced lung injury develops from interactions between the lung parenchyma and applied mechanical power. In acute respiratory distress syndrome, the lung is smaller size with an inhomogeneous structure. ⋯ Volutrauma and atelectrauma harms and benefits, however, seem to be equivalent at 5 to 15 cm H2O. At values greater than 15 cm H2O, the risk of damage outweighs the benefits of major atelectrauma prevention.