Journal of critical care
-
Journal of critical care · Mar 1996
Partial liquid ventilation provides effective gas exchange in a large animal model.
The purpose of this study was to show the ability of partial liquid ventilation (PLV) to sustain gas exchange in normal large (50 to 70 kg) adult animals. ⋯ These data show that during PLV in this normal animal model, effective gas exchange is sustained and CT decreases with increasing perflubron dose.