Cardiac output (CO) measurement is vital in veno-venous extracorporeal membrane oxygenation patient population to evaluate oxygen delivery and to early identify right heart failure. Standard clinical methods like pulmonary artery thermodilution and transpulmonary thermodilution are known to be inaccurate in the veno-venous extracorporeal membrane oxygenation setting, especially at high levels of recirculation. ⋯ The mathematical model and clinical retrospective analysis demonstrates that the new methodology has the potential to accurately measure CO in veno-venous extracorporeal membrane oxygenation patients. The next step is validation in animal and clinical settings.
-
Little is known regarding the potential impact of haematocrit differences in the association between cardiopulmonary bypass reoxygenation and acute kidney injury following Tetralogy of Fallot repair. ⋯ Preoperative haematocrit differences significantly modify the association of perfusate oxygenation with acute kidney injury, highlighting differential control of reoxygenation for different haematocrit children with Tetralogy of Fallot in the management of cardiopulmonary bypass.
-
Gaseous microemboli that originate from the cardiopulmonary bypass circuit may contribute to adverse outcome after cardiac surgery. We prospectively evaluated the influence of gaseous microemboli on the release of various biomarkers after use of a minimally invasive extracorporeal technology system. ⋯ This study showed no evidence that gaseous microemboli contribute to increased biomarker levels after coronary artery bypass grafting with cardiopulmonary bypass. A reason for the absence of damage by gaseous microemboli may be the relative and considerably small amount of gaseous microemboli entering the patients in this study.
-
Effective blood management during cardiac surgery requires a multifactorial effort to limit exposure to allogeneic blood products. The present study evaluated the distribution of intraoperative interventions in patients undergoing coronary artery bypass graft surgery with cardiopulmonary bypass. Records from patients undergoing non-reoperative surgery at 120 hospitals between January 2017 and December 2017 were reviewed, and red blood cell transfusion quartiles established. ⋯ Intraoperative red blood cell units averaged 0.11 ± 0.50 U in low transfusion group compared to 0.63 ± 1.14 U in the high transfusion group. Mixed-effects logistic regression identified first in operating room and first on cardiopulmonary bypass hematocrit, estimated blood volume and nadir hematocrit transfusion trigger as the strongest predictors for red blood cell transfusion. Significant variation exists in the transfusion of red blood cell in coronary artery bypass graft patients undergoing cardiopulmonary bypass which may be related to the application of intraoperative blood management techniques.
-
The benefit of preoperative intra-aortic balloon pump implantation in high-risk cardiac surgery patients is still debated. The role of preoperative intra-aortic balloon pump insertion in acute myocardial infarction patients without cardiogenic shock undergoing off-pump coronary artery bypass grafting remains unknown. This study aimed to determine the efficacy and safety of the preoperative intra-aortic balloon pump insertion in those patients undergoing off-pump coronary artery bypass grafting. ⋯ Preoperative intra-aortic balloon pump insertion in acute myocardial infarction patients without cardiogenic shock undergoing off-pump coronary artery bypass grafting improved convalescence as shown by significantly shorter postoperative lengths of hospital stay.