Comparison of end-tidal carbon dioxide, oxygen saturation and clinical signs for the detection of oesophageal intubation.
The reliability of various methods for detecting oesophageal intubation was assessed by means of a single blind study in rats. Both oesophagus and trachea were simultaneously intubated. The presence or absence of various clinical signs was noted during tracheal or oesophageal ventilation and arterial blood gases and end-tidal CO2 were measured. ⋯ Moisture condensation in the tracheal tube (PPV = 1.0) and abdominal distension (PPV = 0.9) were judged to be the least reliable because each had a high false negative rate of 0.3. The most reliable method for the early detection of oesophageal intubation in rats was end-tidal, CO2 (sensitivity 1.0, specificity = 1.0, PPV = 1.0). In addition, end-tidal CO2 when used in conjunction with the four clinical signs improved the reliability of these signs.