Critical care medicine
-
Critical care medicine · Jun 1998
Mortality is increased by procalcitonin and decreased by an antiserum reactive to procalcitonin in experimental sepsis.
Procalcitonin (ProCT), the precursor to the calcitonin hormone, is abnormally increased in experimental and clinical systemic inflammation, including sepsis. Initially, we investigated the effects of supraphysiologic amounts of ProCT administered to animals with septic peritonitis. Subsequently, we evaluated the efficacy of prophylactic and therapeutic immune blockade of ProCT in this lethal model of sepsis. ⋯ These results demonstrate that increased ProCT exacerbates mortality in experimental sepsis, whereas neutralization of ProCT increases survival. Thus, ProCT, in addition to being an important marker of severity of systemic inflammation and mortality, is an integral part of the inflammatory process and directly affects the outcome.
-
Critical care medicine · Jun 1998
Gut intramucosal pH as an early indicator of effectiveness of therapy for hemorrhagic shock.
To determine the value of intramucosal pH for evaluating the effectiveness of treatment for hemorrhagic shock. ⋯ The change in pHi during the first hour of resuscitation could be used to divide animals treated uniformly from a hemodynamic point of view into two distinct groups with seemingly different outcome. The minimally invasive method could be of value for early evaluation of the results of treatment of hemorrhagic shock.
-
Critical care medicine · Jun 1998
Editorial Comment Comparative StudyOutcome of septic shock: location, location, location.
-
Critical care medicine · May 1998
ReviewPortable devices used to detect endotracheal intubation during emergency situations: a review.
To review the operational characteristics of commercial devices used to detect endotracheal intubation; and to identify an ideal device for detecting endotracheal intubation in emergency situations, especially in the prehospital setting during cardiac arrest. ⋯ Although no clinical comparative study of commercial devices to detect endotracheal intubation exists, the syringe device (TubeChek) has most of the characteristics necessary for a device to be considered ideal in emergency situations in the prehospital setting. It is simple, inexpensive, easy to handle and operate, disposable, does not require maintenance, gives reliable results for patients with and without cardiac arrest, and can be used for almost all age groups. The device may yield false-negative results, most commonly in the presence of copious secretions and in cases of accidental endobronchial intubation. Regardless of the device used, clinical judgment and direct visualization of the endotracheal tube in the trachea are required to unequivocally confirm proper endotracheal tube placement.