The Journal of arthroplasty
-
Corrosion at the modular neck-stem taper junction has become an increasingly important topic as several reports have identified this couple as a possible source for early failure with findings similar to failed metal-on-metal hip arthroplasties. Recently, two different modular stem systems from a single manufacturer were voluntarily recalled due to concerns of failure of the modular taper junction. ⋯ We further reviewed the literature to evaluate whether this is a manufacturer-specific defect or indicative of a broader trend. Recent studies appear to implicate the basic design of the neck-stem taper junction, rather than a single manufacturer, which is at high risk for fretting and corrosion.
-
We assessed the association of cerebrovascular disease preoperatively with patient-reported outcomes (PROs) of moderate-severe activity limitation and moderate-severe pain at 2- and 5-years after primary total knee arthroplasty (TKA) using multivariable-adjusted logistic regression; 7139 primary and 4234 revision TKAs were included. Compared to the patients without cerebrovascular disease, those with cerebrovascular disease had a higher odds ratio (OR) of moderate-severe limitation at 2 years and 5 years, 1.32 (95% confidence interval [CI]: 1.02, 1.72; P = .04) and 1.83 (95% CI: 1.32, 2.55; P < .001), respectively. ⋯ In conclusion, we found that cerebrovascular disease is independently associated with pain and function outcomes after primary TKA. This should be taken into consideration when discussing expected outcomes of TKA with patients.
-
The following study is a review of 3 different treatment methods for treating comminuted distal periprosthetic femur fractures in 23 patients over the age of 70 (average age 80, range 70-90). Reconstruction techniques included 7 allograft prosthesis composite (APC), 9 revision systems (RSA), and 7 distal femur endoprosthesis (DFR). ⋯ No significant difference was found in the 6-week or 6-month Knee Society Scores. Our preliminary results demonstrate that in experienced hands, distal femur endoprosthesis should be considered in patients with advanced age and poor bone quality who require early mobilization.
-
The stability of prosthetic fixation is to a large extent dependent on component design. The purpose of this study is to analyze the short-term radiological results obtained with the Wagner Standard Cup in primary hip arthroplasty. An assessment was made of one hundred primary hip arthroplasties. ⋯ In summary, osseointegration of the Wagner Standard Cup was unsuccessful in a high percentage of cases. This finding, which was unrelated to the type of stem or bearing surface used, bore a statistically significant relation (P<0.05) with an observed poor bone coverage of the acetabular component. Although insufficient bone coverage could arguably be attributable to a poor surgical technique, we would tend to agree with other authors that it is rather likely to result from a flawed implant design that impedes osseointegration.