The Journal of arthroplasty
-
Nationwide, computer-based reporting of all arthroplasties performed in Finland was started in January 1980. Using data from these records, a cohort of 31,651 polyethylene-on-metal total hip arthroplasty (THA) patients was followed up for cancer, using Finnish Cancer Registry data, from 1980 to 1995. During follow-up, 2,367 cancers were observed. ⋯ SIRs relating to soft tissue cancers and bone sarcomas did not differ significantly from unity. No sarcoma was observed at the site of a prosthesis. THA seems to play no major role in cancer causation.
-
The postoperative leg-length discrepancy was determined radiographically for a consecutive series of 351 patients (408 hips) who underwent bilateral or unilateral primary total hip replacement using a single method of leg-length equalization by preoperative planning with overlay templates. The method of equalization was performed by a measurement of the femoral head and neck segment to be resected from a reference point at the superior aspect of the dislocated femoral head. The amount of femoral bone resected was determined preoperatively by determining the dimensions of the acetabular component thickness and the femoral component head and neck height that would be replacing this resected bone and adjusting this distance for any preexisting leg-length discrepancy. ⋯ Postoperative leg lengths were determined radiologically from a measurement from the acetabular teardrop to the lesser trochanter. Ninety-seven percent of the patients had a postoperative leg-length discrepancy that was less than 1 cm, and 86% had a leg-length difference that was 6 mm (1/4 inch) or less. The average postoperative discrepancy for these 351 patients was 1 mm.
-
Cerclage wires have been used to stabilize proximal femoral cracks after stem insertion in cementless total hip arthroplasty. The objective of this study was to determine the optimal number and orientation of cerclage wires necessary to prevent stem subsidence and crack propagation. The crack was stabilized by 1, 2, or 3 wires placed either normal to the femoral neck axis or normal to the crack. ⋯ Wires placed normal to the crack allowed less stem subsidence by 3.17 mm and less crack opening by 1.55 mm compared with wires placed normal to the neck. The addition of multiple wires reduced subsidence by 50% and reduced crack opening to <1 mm. Medial and anterior calcar cracks are best stabilized by at least 2 cerclage wires that are placed normal to the crack.
-
The diagnosis of aseptic loosening in total hip arthroplasty is predominantly based on clinical and radiographic evaluation. Loosening is usually associated with increased bone resorption at the interface. In this study we wanted to evaluate the diagnostic value of bone markers in aseptic loosening. ⋯ We found significantly increased levels of NTX, DPYD, PYD, and OC in the loosening group. The other markers showed no significant difference between both groups. We conclude that determination of urinary crosslinks may offer a new and valuable diagnostic method in the detection of aseptic loosening in total hip arthroplasty.
-
Financial analysis of 391 joint replacement operations performed during 1996 determined that almost 80% of the hospital cost for joint replacement procedures was generated in the operating room, nursing units, recovery room, and pharmacy during the first 48 hours of hospitalization. Attempts to control or reduce the hospital cost of joint replacement operations should focus on these specific areas of opportunity.