Journal of Korean medical science
-
J. Korean Med. Sci. · Feb 2016
Survey of Thoracic CT Protocols and Technical Parameters in Korean Hospitals: Changes before and after Establishment of Thoracic CT Guideline by Korean Society of Thoracic Radiology in 2008.
We retrospectively reviewed the thoracic CT scan protocols and technical parameters obtained from hospitals in Korea, one group during May 2007 (n = 100) and the other group during January 2012 (n = 173), before and after the establishment of the thoracic CT Guideline in 2008. Each group was also divided into two subgroups according to the health care delivery level, i.e. the "A" subgroup from primary and the "B" subgroup from secondary and tertiary care hospitals. When comparing the data from 2007 and 2012, the tube current decreased from 179.1 mAs to 137.2 mAs. ⋯ In conclusion, during the five-year time period between 2007 and 2012, a reduction in the tube current values was seen. And the overall image quality improved over the same time period. We assume that these changes are attributed to the implementation of the thoracic CT guideline in 2008.
-
J. Korean Med. Sci. · Feb 2016
Falls in Korean Polio Survivors: Incidence, Consequences, and Risk Factors.
Falls and fall-related injuries are important issue among polio survivors. The purpose of this study was to determine the incidence of, and consequences and factors associated with falls among Korean polio survivors. A total of 317 polio survivors participated in this study. ⋯ Female sex, old age, low bone mineral density, the presence of symptoms related to post-polio syndrome (PPS), poor balance confidence, short physical performance battery and weak muscle strength of knee extensor were not significantly associated with falls. Only leg-length discrepancy using spine-malleolar distance (SMD) was a significant factor associated with falls among Korean polio survivors. Our findings suggest that malalignment between the paralytic and non-paralytic limb length should be addressed in polio survivors for preventing falls.
-
J. Korean Med. Sci. · Feb 2016
Radiation Dose from Whole-Body F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Nationwide Survey in Korea.
The purpose of this study was to estimate average radiation exposure from (18)F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) examinations and to analyze possible factors affecting the radiation dose. A nation-wide questionnaire survey was conducted involving all institutions that operate PET/CT scanners in Korea. From the response, radiation doses from injected FDG and CT examination were calculated. ⋯ Advanced PET technologies such as time-of-flight acquisition and point-spread function recovery were also related to low radiation dose (P < 0.001). In conclusion, the average radiation dose from FDG PET/CT is estimated to be 12.2 mSv. The radiation dose from FDG PET/CT is reduced with more recent scanners equipped with image-enhancing algorithms.