Annals of biomedical engineering
-
This work presents a portable non-invasive external fixator to assess and monitor fracture healing in real time. To evaluate the potential of this fixator, a transverse osteotomy was performed in the tibia of six adult sheep (mean age 3+/-0.5 years and weight 63+/-5 kg). The fractures were stabilized by a specially designed unilateral external fixator, which was instrumented by means of a set of strain gauges. ⋯ Full weight bearing of the injured leg was observed from the beginning. The load transmission mechanism in the fixator was quite similar in all operated tibias and radiographic images showed a successful healing in all animals. Although the fixator has only been tested in an animal model, after further testing this system may have clinical potential.
-
The multiple inert gas elimination technique (MIGET) provides a method for estimating alveolar gas exchange efficiency. Six soluble inert gases are infused into a peripheral vein. Measurements of these gases in breath, arterial blood, and venous blood are interpreted using a mathematical model of alveolar gas exchange (MIGET model) that neglects airway gas exchange. ⋯ The MIGET mathematical model predicted distributions of ventilation and perfusion for each grouping of gases and multiple perturbations of VA/Q and Qbr. Using the modified MIGET gases, MIGET predicted a smaller dead space fraction, greater mean VA, greater log(SDVA), and more closely matched the imposed VA distribution than that using the standard MIGET gases. Perfusion distributions were relatively unaffected.
-
There is considerable interest in non-intrusive and reliable continuous ambulatory blood pressure measurement systems. Pulse amplitude is the peak to trough amplitude of the photo-plethysmogram signal. We compared pulse amplitude with a currently popular parameter, the pulse arrival time (PAT), for estimating continuous systolic blood pressure (SBP). ⋯ SBP estimation errors were significantly lower using pulse amplitude [p<0.001, 95% CI: -1.55 to -1.29 mmHg (finger), -0.53 to -0.36 mmHg (wrist)]. We also found that while pulse amplitude was closely related to SBP, the relationship weakened during and around REM sleep (ANOVA of REM, transitional Wake-REM and transitional REM-Sleep versus other sleep states: F=24.7, p<0.001). These results suggest that pulse amplitude is potentially a more suitable measure than pulse arrival time for estimating continuous blood pressure.
-
Recently a new method has been proposed as a tool to measure arterial pulse wave velocity (PWV), a measure of the stiffness of the large arteries and an emerging parameter used as indicator of clinical cardiovascular risk. The method is based on measurement of brachial blood pressure during supra-systolic pressure inflation of a simple brachial cuff [the device is known as the Arteriograph (Tensiomed, Budapest, Hungary)]. This occlusion yields pronounced first and secondary peaks in the pressure waveform, the latter ascribed to a reflection from the aortic bifurcation, and PWV is calculated as the ratio of twice the jugulum-symphysis distance and the time difference between the two peaks. ⋯ Both PWVATG (R2=0.94) and PWVcar-fem (R2=0.95) correlated well with PWVtheor, but their numerical values were lower (by 2.17+/-0.42 and 1.08+/-0.70 m/s for PWVATG and PWVcar-fem, respectively). In conclusion, our simulations question the working principle of the Arteriograph. Our data indicate that the method picks up wave reflection phenomena confined to the brachial artery, and derived values of PWV rather reflect the stiffness of the brachial arteries.
-
Replacement of a degenerated vertebral disc with an artificial intervertebral disc (AID) is currently possible, but poses problems, mainly in the force distribution through the vertebral column. Data on the intervertebral disc space geometry will provide a better fit of the prosthesis to the vertebrae, but current literature on vertebral disc geometry is very scarce or not suitable. In this study, existing CT-scans of 77 patients were analyzed to measure the intervertebral disc and vertebral endplate geometry of the lumbar spine. ⋯ It was found that the largest endplate depth is located in the middle or posterior regions of the vertebra, that there is a linear relationship between all inferior endplate depths and the endplate location (p < 0.0001) within the spinal column, and that the superior endplate depth increases with age by about 0.01 mm per year (p < 0.02). The wedge angle increases from T12-L1 to L5-S1. The results allow for improvement of the fit of intervertebral disc-prostheses to the vertebrae and optimized force transmission through the vertebral column.