Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
-
Transesophageal echocardiography provides high resolution of intracardiac structures. One potential problem is the misdiagnosis of previously unrecognized benign cardiac structures as malignant processes, leading to unnecessary surgical procedures. We describe an unusual case of benign intracardiac eustachian valve cyst monitored over 2 years.
-
Abdominal aortic aneurysm (AAA) is associated with atherosclerosis elsewhere. Thoracic aortic atheromas (ATHs) seen on transesophageal echocardiography (TEE) are an important cause of stroke and peripheral embolization. The purposes of this study were to determine whether an association exists between AAA and ATHs and to assess the importance of screening patients with ATHs for AAA. ⋯ (1) There is a strong, highly significant association between abdominal aneurysm and thoracic atheromas. (2) Patients with AAA may be at high risk for stroke because of the concomitance of thoracic aortic atheromas. (3) The high prevalence of abdominal aneurysm in patients with thoracic atheromas suggests that screening for abdominal aneurysm should be carried out in all patients with thoracic atheromas identified by TEE.
-
J Am Soc Echocardiogr · Oct 2001
The validation of volumetric real-time 3-dimensional echocardiography for the determination of left ventricular function.
The objective of this study was to validate a real-time 3-dimensional echocardiography (3DE) technique for the determination of left ventricular (LV) volume and ejection fraction (EF). In 10 mongrel dogs, an electromagnetic flow (EMF) probe was placed on the aorta, and the thorax was closed. Transthoracic imaging was performed during multiple hemodynamic conditions (n = 58) with simultaneous measurement of stroke volume (SV) with the use of EMF. ⋯ Interobserver and intraobserver variabilities were comparable (r = 0.94 and r = 0.94, respectively). In a comparison of MUGA-derived EF values and those obtained by 3DE in human subjects, 3DE provided better correlation than the biplane method (r = 0.94 versus r = 0.85). Real-time 3DE accurately measures left ventricular volumes transthoracically over a wide range of hemodynamic conditions in dogs and accurately determines EF in humans.
-
J Am Soc Echocardiogr · Oct 2001
Case ReportsPatent foramen ovale presenting as platypnea-orthodeoxia: diagnosis by transesophageal echocardiography.
Platypnea-orthodeoxia is a rare syndrome that is often associated with interatrial shunting through a patent foramen ovale or atrial septal defect. We describe the case of a 65-year-old woman with progressive dyspnea and hypoxia when standing and walking, which was relieved by assuming the recumbent position. The diagnosis was confirmed by tilt-table transesophageal echocardiography demonstrating a large right-to-left shunt through a patent foramen ovale while the patient was in a semiupright position and no significant shunt while in a recumbent position. This case demonstrates that platypnea-orthodeoxia caused by a patent foramen ovale can be clearly demonstrated by the technique of contrast transesophageal echocardiography performed on a tilt table.
-
J Am Soc Echocardiogr · Sep 2001
Impact of intraoperative transesophageal echocardiography among patients undergoing aortic valve replacement for aortic stenosis.
In this study, we sought to define the impact of intraoperative transesophageal echocardiography (IOTEE) among patients undergoing aortic valve replacement for severe aortic stenosis. We reviewed the clinical data and preoperative, intraoperative, and postoperative echocardiograms of all adults who underwent aortic valve replacement for aortic stenosis and had IOTEE between January 1993 and December 1996. There were 383 patients (223 men, 160 women; mean age, 69 years). ⋯ Additional information was found by IOTEE in 25 patients before and after bypass, altering the surgical plan in 18 of these 25 patients. Overall, IOTEE altered the planned operation in 49 (13%) of the 383 patients. These data support the routine use of IOTEE among patients undergoing aortic valve replacement for aortic stenosis.