Journal of orthopaedic trauma
-
Twelve of 14 proximal third tibial shaft fractures were successfully treated with a new technique for intramedullary nailing of these fractures. The average anterior displacement was 3.0 mm (range 0-17). ⋯ There was one nonunion. The technique's success is dependent on neutralizing the primary factors causing malreduction: wide effective diameters of tibial nails, narrow diameter of the medial tibial metaphysis, and a posteriorly directed sagittal plane entrance angle.