Journal of radiological protection : official journal of the Society for Radiological Protection
-
Multicenter Study
Derivation of new diagnostic reference levels for neuro-paediatric computed tomography examinations in Switzerland.
Definition of new national diagnostic reference levels (DRLs) for volume computed tomography dose index (CTDIvol) and dose length product (DLP) for neuro-paediatric CT examinations depending on the medical indication. ⋯ This study provides Swiss neuro-paediatric CT DRL values to establish optimum conditions for paediatric cranial CT examinations. Periodic national updates of DRLs, following international comparisons, are essential.
-
We found some trivial errors which might confuse reader. The errors can be identified as the following two types. (1) The one is that misuse of "ERR" and "ERR/Sv". We denoted "Table 4 shows ERRs/Sv and 90% CIs ..." in line 7 of page 366. ⋯ These are correct description. However, "ERR with adjustment for smoking" was described as "For smoking" in Table 2. In addition, "Without adjustment" and "With adjustment" denoted in the surface caput of Table 5, 6, 7 should be denoted as "Without adjustment for smoking" and "With adjustment for smoking". The author wishes to apologies for the errors. .
-
Multicenter Study
Ionizing radiation exposure in interventional cardiology: current radiation protection practice of invasive cardiology operators in Lithuania.
Ionizing radiation management is among the most important safety issues in interventional cardiology. Multiple radiation protection measures allow the minimization of x-ray exposure during interventional procedures. Our purpose was to assess the utilization and effectiveness of radiation protection and optimization techniques among interventional cardiologists in Lithuania. ⋯ Median effective patient doses were significantly lower with x-ray optimization techniques in both diagnostic and therapeutic interventions. Many of the ionizing radiation exposure reduction tools and techniques are underused by a considerable proportion of interventional cardiology operators. The application of basic radiation protection tools and techniques effectively reduces ionizing radiation exposure and should be routinely used in practice.
-
Those working in interventional cardiology and related medical procedures are potentially subject to considerable exposure to x-rays. Two types of tissue of particular concern that may receive considerable doses during such procedures are the lens of the eye and the brain. Ocular radiation exposure results in lens changes that, with time, may progress to partial or total lens opacification (cataracts). ⋯ Although absorbed doses to the brain in interventional cardiology procedures are lower than those to the eye lens by a factor between 3.40 and 8.08 according to our simulations, doses to both tissues are among the highest occupational radiation doses documented for medical staff whose work involves exposures to x-rays. We present InterCardioRisk, a tool featuring an easy-to-use web interface that provides a general estimation of both cumulated absorbed doses experienced by medical staff exposed in the interventional cardiology setting and their estimated associated health risks. The tool is available at http://intercardiorisk.creal.cat.
-
Some shortcomings regarding safety have emerged in inspections by the Swedish Radiation Safety Authority of Swedish radiology departments which perform 5.4 million radiological examinations and 100 000 nuclear scans annually. To ensure safety in the healthcare system and to build a strong environment of radiation protection for patients (and for employees) there must be a strong culture of safety. To understand an organization's behaviour, decisions and actions it is important to study its cultural values. ⋯ The majority attitudes were based on experiences associated with aspects that the radiologist could not influence. This often concerns increased pressure on radiology investigations from clinics in the various operational units. Under the concept of norms, the radiologists in the study requested that the development of regulations and guidelines should be connected to issues of justification for various radiological queries.