The effects of arterial blood gas values on lesion volumes in a graded rat spinal cord contusion model.
The detrimental effects of extreme blood gas values are well documented. However, the range of normal values has not been rigorously defined. There is an ongoing debate concerning the need for ventilation and tight control of blood gas values in spinal cord injury models. ⋯ The effects of blood gas values on ionic lesion volumes are not statistically significant unless the data are adjusted for injury severity. Although blood gas values must be carefully monitored, ventilation may not be needed routinely in rat spinal cord injury models. We recommend maintaining pH values between 7.35 and 7.40, PaCO2 between 35 and 41 mm Hg, and PaO2 greater than 71 mm Hg.