Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine
-
Proc Inst Mech Eng H · Nov 2011
Development and in vitro evaluation of a flow-adjustable elastic drug infusion pump.
Passive-type drug infusion pumps have several advantages over active-type pumps including a simple drug chamber structure and relatively high operational stability. However, conventional passive-type infusion pumps also have several limitations compared to active ejection pumps, such as a fixed flowrate and monotonic flow pattern. To enhance the clinical feasibility of using passive-type drug infusion pumps, flow readjustment and flow regulation abilities are needed. ⋯ Experiments on the proposed system resulted in actual injection rates of 0.49 +/- 0.03 (mean +/- standard deviation), 0.98 +/- 0.03, 1.49 +/- 0.04, and 1.99 +/- 0.03 ml/h when the target injection rate was set to 0.5, 1.0, 1.5, and 2.0 ml/h, respectively. During the entire period of operation from the fully filled state to the totally empty state, an inner-chamber pressure of >100 mmHg was maintained, which shows that the proposed infusion pump can stably maintain its target flowrate as the amount of drug remaining to be injected decreases. It appears that the proposed drug infusion pump can be applied to a wide variety of patient treatments that require short-term, accurate, and stable drug delivery.
-
Proc Inst Mech Eng H · Sep 2011
The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant: the effect of cable-screw position.
Optimal surgical positioning of cable-screw pairs in repairing periprosthetic femur fractures near the tip of a total hip implant still remains unclear. No studies in the literature to date have developed a fully three-dimensional finite element (FE) model that has been validated experimentally to assess these injury patterns. The aim of the present study was to evaluate the biomechanical performance of three different implant-bone constructs for the fixation of periprosthetic femoral shaft fractures following total hip arthroplasty. ⋯ FE surface stress maps for cortical bone showed maximum von Mises values of 74 MPa (Construct A), 102 MPa (Construct B), and 57 MPa (Construct C). FE stress maps for the metallic components showed minimum von Mises values for Construct C, namely screw (716MPa), cable (445MPa), plate (548MPa), and hip implant (154MPa). In the case of good bone stock, as modelled by the present synthetic femur model, optimal fixation can be achieved with Construct C.
-
Proc Inst Mech Eng H · Sep 2011
The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?
Femoral shaft fractures after total hip arthroplasty (THA) remain a serious problem, since there is no optimal surgical repair method. Virtually all studies that examined surgical repair methods have done so clinically or experimentally. The present study assessed injury patterns computationally by developing three-dimensional (3D) finite element (FE) models that were validated experimentally. ⋯ Cables absorbed the majority of load, followed by the plates and then the screws. Construct A yielded peak stress at one of the empty holes in the plate. Constructs B and C had similar bone stress patterns, and can achieve optimal fixation.
-
Proc Inst Mech Eng H · Jun 2011
Experimental study and model validation of selective spinal cord and brain hypothermia induced by a simple torso-cooling pad.
In vivo experiments have been performed to test the effectiveness of a torso-cooling pad to reduce the temperature in the spinal cord and brain in rats. Coolant was circulated through the cooling pad to provide either mild or moderate cooling. Temperatures in the brain tissue, on the head surface, and on the spine and back surfaces were measured. ⋯ Using experimental data, theoretical models of the rat head and torso were developed to predict the regional temperatures and to validate the rat models. There was good agreement between the theoretical and experimental temperatures in the torso region. Differences between the predicted and measured temperatures in the brain are likely to be the result of imperfect mixing between the cold spinal fluid and the warm cerebrospinal fluid that surrounds the brain.
-
Proc Inst Mech Eng H · May 2011
Evaluation of a new computer-assisted surgical planning and navigation system based on two-dimensional fluoroscopy for insertion of a proximal femoral nail: an experimental study.
Pertrochanteric femoral fractures are common and intramedullary nailing is an accepted method for their surgical treatment. Accurate placement of the implant is essential to ensure fixation. The conventional technique can require multiple guide wire passes, and relies heavily on fluoroscopy. ⋯ The operation time was significantly longer in the navigation-assisted group. The addition of computer-assisted planning and surgical guidance to the intramedullary nailing of pertrochanteric femoral fractures offers a number of clinical benefits based on the results of this sawbone study. Further studies including fractured sawbones and cadaver models with extension of the navigation process to all steps of PFNA introduction and with the goal of reducing operation time are indispensable before integration of this navigation system into clinical practice.