Archives of orthopaedic and trauma surgery
-
Arch Orthop Trauma Surg · Jul 2015
Case ReportsLaser engravings as reason for mechanical failure of titanium-alloyed total hip stems.
Two revisions of broken β-titanium total hip stems had to be performed in our hospital after 2 and 4 years in situ. Since both fractures were located at the level of a laser engraving, a failure analysis was conducted. ⋯ Laser engravings need to be reduced to a minimum of necessary information, and should be placed at locations with minimum mechanical load. Biomechanical analyses are recommended to identify less loaded areas in implant components to avoid such implant failures.
-
Arch Orthop Trauma Surg · Jul 2015
A new universal, standardized implant database for product identification: a unique tool for arthroplasty registries.
Every joint registry aims to improve patient care by identifying implants that have an inferior performance. For this reason, each registry records the implant name that has been used in the individual patient. In most registries, a paper-based approach has been utilized for this purpose. However, in addition to being time-consuming, this approach does not account for the fact that failure patterns are not necessarily implant specific but can be associated with design features that are used in a number of implants. Therefore, we aimed to develop and evaluate an implant product library that allows both time saving barcode scanning on site in the hospital for the registration of the implant components and a detailed description of implant specifications. ⋯ The implant library that was developed for the German Arthroplasty Registry allows not only on-site barcode scanning for the registration of the implant components but also its classification tree allows a sophisticated analysis regarding implant characteristics, regardless of brand or manufacturer. The database is maintained by the implant manufacturers, thereby allowing registries to focus their resources on other areas of research. The database might represent a possible global model, which might encourage harmonization between joint replacement registries enabling comparisons between joint replacement registries.
-
Arch Orthop Trauma Surg · Jul 2015
The course of the median and radial nerve across the elbow: an anatomic study.
Nerve transection has been described as complication of arthroscopic elbow arthrolysis. Therefore, the goal of this study was to define bony landmarks for intraoperative orientation regarding the location of the median and radial nerve. ⋯ The radial nerve is located ventral to the central third of the capitulum. The median nerve lies ventral to the medial quarter of the humeral condyle. When performing arthroscopic arthrolysis, this information should be kept in mind during anterior capsulectomy.