Archives of orthopaedic and trauma surgery
-
Arch Orthop Trauma Surg · Nov 2020
Difficult to treat: are there organism-dependent differences and overall risk factors in success rates for two-stage knee revision?
Failure after two-stage procedure for periprosthetic joint infection (PJI) is a rare, but devastating complication. Some authors assume a correlation of underlying organisms and recurrence rate. Methicillin-resistant Staphylococci (MRS) and other organisms (quinolone-resistant Gram-negative bacteria, rifampicin-resistant Staphylococcus, Enterococcus, and Candida) are meant to be "difficult to treat" (DTT) with an inferior outcome for two-stage revision. In addition to the type of bacteria, some more risk factors seem to be present. The aim of this study was (1) to detect a difference of reinfection rates between reinfection-causing groups of bacteria ["difficult to treat" (DTT), "easy to treat" (ETT) and methicillin-resistant staphylococci (MRS)] after a two-stage procedure, and (2) find overall risk factors for reinfection in a standardized long (spacer insertion for at least 6 weeks) two-stage procedure for periprosthetic knee infection. ⋯ Revision needed during or after a two-stage exchange, numbers of surgeries and alcohol abuse are risk factors for recurrence, a different recurrence rates between organism-groups cannot be shown. The absence of significant differences in recurrence rates points to the importance of the individuality of each periprosthetic infection case: a reduction of necessary surgeries (with a thorough debridement, appropriate antibiotic addition to spacers) and the control of comorbidities (alcohol abuse) appear to be essential components of a two-stage exchange.
-
Arch Orthop Trauma Surg · Nov 2020
High risk of hip dislocation following polyethylene liner exchange in total hip arthroplasty-is cup revision necessary?
Polyethylene (PE) wear remains a common reason for revision surgery following total hip arthroplasty (THA). An established treatment method is isolated liner exchange in a well-fixed acetabular cup and entails a known high risk of hip dislocation after revision surgery. The purpose of this retrospective study was to determine the rate of hip dislocation after liner exchange. ⋯ In conclusion, isolated exchange of the polyethylene liner because of wear showed a high risk of dislocation and further cup revision. Our results suggest that the threshold for revising well-fixed components in the case of liner wear should be lowered.