Archives of orthopaedic and trauma surgery
-
Arch Orthop Trauma Surg · Dec 2020
Two-year clinical results of a novel load redistribution device for the treatment of medial knee OA.
A potential method to relieve the pain from medial osteoarthritis of the knee is to offload the medial compartment. The Latella™ Knee Implant is a novel device designed to offload the medial compartment. The objective of the Cotera-1 study was to evaluate the preliminary safety and feasibility of the Latella implant to treat patients with medial OA of the knee, by a 2-year follow-up of a prospective multicenter feasibility study (Cotera-1) performed in the Netherlands and UK METHODS: In this first-in-man study, 11 participants received the Latella implant and were followed for 2 years, documenting physician assessment, Patient-Reported Outcome (PRO) scoring (KOOS, IKDC, Kujala, SF-36); Patient Global Assessment (PGA), radiographic analysis and MRI analysis, complications, reoperation rate and hip-knee-ankle axis. ⋯ II.
-
Arch Orthop Trauma Surg · Dec 2020
A detaching, V-shaped tibial tubercle osteotomy is a safe procedure with a low complication rate.
In patients with recurrent patellar dislocations, a tibial tubercle osteotomy (TTO) can be indicated to correct patella alta or an increased trochlear groove-tibial tubercle distance. Several surgical techniques are described. Previous studies emphasize that detaching osteotomies results in devascularisation, which can lead to non-union and tibial shaft fractures. The aim of this study was to report the complication rates directly related to the surgical technique of a V-shaped TTO, where the tubercle is completely released from its periosteum using a step-cut osteotomy. ⋯ A V-shaped TTO is a safe procedure. The presumed higher risk for tibial fractures or pseudo-arthrosis could not be confirmed.
-
Arch Orthop Trauma Surg · Dec 2020
Case ReportsBowing-head sign: rare but detectable in pre-catastrophic hip implant failure.
Recently, catastrophic failure (i.e., dissociation between the metal femoral head and stem due to stem neck deformation) after total hip arthroplasty (THA) has been reported. Early detection of this complication is very important, because it is accompanied by an increased cobalt concentration in the body, which might influence systemic conditions such as heart failure and immune system diseases. However, early detection of stem neck deformation is considered as difficult. ⋯ Laboratory data showed abnormal serum cobalt (6.3 μg/L, normal < 1 μg/L) and chromium (3.8 μg/L, normal < 5 μg/L) levels. Considering those radiographic findings, deformation of the stem neck due to trunnionosis was diagnosed, and elective revision surgery was performed without any complications. Plain radiographs after THA should be assessed with attention to this complication, 'Bowing-head sign' must not be overlooked.
-
Arch Orthop Trauma Surg · Dec 2020
Randomized Controlled Trial Multicenter StudyVitamin E-blended highly cross-linked polyethylene liners in total hip arthroplasty: a randomized, multicenter trial using virtual CAD-based wear analysis at 5-year follow-up.
Progressive oxidation of highly cross-linked ultra-high molecular weight (UHMPWE-X) liners is considered to be a risk factor for material failure in THA. Antioxidants such as vitamin E (alpha-tocopherol) (UHMWPE-XE) were supplemented into the latest generation of polyethylene liners. To prevent inhomogenous vitamin E distribution within the polymer, blending was established as an alternative manufacturing process to diffusion. The purpose of the present study was to investigate the in vivo wear behavior of UHMWPE-XE in comparison with conventional UHMWPE-X liners using virtual CAD-based radiographs. ⋯ The present study demonstrates that the addition of vitamin E does not adversely affect the midterm wear behavior of UHMWPE-X. The antioxidative benefit of vitamin E is expected to become evident in long-term follow-up. Cup anteversion increment by 5° within the 1st year is likely a result of the released hip flexion contracture resulting in an enhanced posterior pelvic tilt. Therefore, a reassessment of target values in acetabular cup placement might be considered.
-
Arch Orthop Trauma Surg · Dec 2020
Case ReportsArthroscopic treatment of a one-fourth anteroinferior glenoid comminuted fracture-dislocation with concomitant three-part complex proximal humerus fracture in a middle-aged man: a case report.
Proximal humeral fracture-dislocations can occur in high-energy traumas. This injury can be accompanied by a glenoid fracture; however, it is a rare type of complex injury in patients aged under 60 years. ⋯ We confirmed bony union of the fracture sites after 6 months post-surgery. The patient showed excellent clinical outcomes with a nearly full range of motion without instability CONCLUSIONS: We reported a successful outcome for a complex proximal humeral fracture involving the glenoid using closed reduction and fixation for the proximal humeral fracture and arthroscopic reduction and fixation for the comminuted anteroinferior glenoid fracture.