The role of femoral head size in metal-on-metal hip arthroplasty: analysis of a cohort of 3813 patients with long term follow-up.
Metal-on-metal (MoM) large headed arthroplasties were suggested to decrease failure rates by means of reduced volumetric wear and enhanced implant stability. However, they caused high rates of revisions due to adverse reaction to metal debris, osteolysis, pseudotumor growth, and other issues. The study aims to present the long-term outcomes of MoM arthroplasties on a large cohort of patients, evaluating the impact of head sizes on survival rate. ⋯ Gender, patient's age and the use of modular neck were not correlated with higher failure rates. MoM implants implants do not have the same reliability as other couplings, considering the significantly greater failure/complication rates. However, the knowledge of risks linked to head size is fundamental for establishing the right type of follow-up to the patient and recognize any complications early.