Archives of orthopaedic and trauma surgery
-
Arch Orthop Trauma Surg · Jul 2024
Comparison of the use of biocompatible materials and titanium in the treatment of midshaft clavicle fractures with a patient-specific plate: a finite element analysis study.
Clavicular midshaft fractures treated with titanium plates may encounter complications like implant failure. We assess if alternative biocompatible materials suchs as PLA, PLA/HA, PEEK offer comparable stability. Our study evaluates the biomechanical performance of these materials in surgical management of midshaft clavicle fractures. ⋯ Our findings indicate that titanium material shows significantly higher stresses on plates and screws compared to those on the clavicle, suggesting a risk of implant failure. PLA and PLA/HA were inadequate for fixation. Although stress on the plate with PEEK material is higher than on the clavicle, it remains lower than titanium, indicating potential stability at fracture site. Further research is needed to confirm these findings.
-
Arch Orthop Trauma Surg · Jul 2024
ReviewSafety evaluation of outpatient vs inpatient unicompartmental knee arthroplasty: a systematic review and meta-analysis.
This systematic review and meta-analysis aimed to evaluate the safety of outpatient and inpatient Unicompartmental Knee Arthroplasty (UKA) based on the incidence of adverse events. ⋯ In summary, outpatient UKA shows lower incidences of hospital-acquired complications such urinary tract infection, pulmonary embolus, and transfusion. It's worth noting that the incidences of total complications, readmission, and venous thrombosis in outpatient UKA were not higher than the incidences of inpatient UKA, suggestting that outpatient UKA can be considered a safe alternative to inpatient UKA.
-
Arch Orthop Trauma Surg · Jul 2024
Influence of broach surface design of a fully hydroxyapatite coated, double tapered stem on periprosthetic bone mineral density after total hip arthroplasty: a study based on the morphology of the proximal femur.
This study aimed to compare the impact of different broach surface designs on post-operative clinical outcomes, bone reactions and changes in bone mineral density (BMD) in patients who underwent total hip arthroplasty (THA) using a fully hydroxyapatite coated and double tapered stem with either compaction shape (COM) or hybrid shape (HYB) broaches. ⋯ This study suggests that the broach surface design of fully hydroxyapatite coated stems may influence periprosthetic BMD changes, especially in Dorr type A and B femurs. Surgeons should consider broach selection based on patient-specific femoral morphology to optimize BMD preservation in THA procedures using fully hydroxyapatite coated stems.
-
Arch Orthop Trauma Surg · Jul 2024
Reconstruction of mechanical leg axis using non-modular cemented hinged prosthesis in complex primary total knee arthroplasty.
Modular cementless knee arthroplasty systems are capable of precise reconstruction of the mechanical axis. However, they are considered more susceptible to complications. In contrast, non-modular cemented systems are said to be more forgiving and show good long-term results. The aim of this study was to investigate the resulting leg axis after implantation of a non-modular cemented rotating hinged knee prosthesis. Furthermore, potential risk factors for the occurrence of malalignment and complications should be identified. ⋯ Level III: Retrospective cohort study.
-
Arch Orthop Trauma Surg · Jul 2024
Establishing minimal clinically important differences and patient acceptable symptom state thresholds following birmingham hip resurfacing.
Birmingham Hip Resurfacing (BHR) has emerged as a compelling and innovative alternative to total hip arthroplasty (THA), especially among young, active patients. However, the Minimal Clinically Important Difference (MCID) and the Patient Acceptable Symptom State (PASS) thresholds have not yet been determined for patients undergoing BHR. Therefore, the current study aimed to (1) determine the MCID and PASS thresholds for both the Hip disability and Osteoarthritis Outcome Score (HOOS)-Pain and HOOS physical function shortform (PS), for patients who underwent BHR; and (2) identify factors influencing the achievement of MCID and PASS for HOOS-Pain and HOOS-PS. ⋯ MCID and PASS thresholds were established for HOOS-Pain and PS domains following BHR with most patients achieving these clinically meaningful benchmarks. Additionally, several factors affecting achievement of MCID and PASS were identified, including modifiable risk factors that may allow clinicians to implement optimization strategies and further improve outcomes.