Monosegmental anterior column reconstruction using an expandable vertebral body replacement device in combined posterior-anterior stabilization of thoracolumbar burst fractures.
In combined posterior-anterior stabilization of thoracolumbar burst fractures, the expandable vertebral body replacement device (VBRD) is typically placed bisegmentally for anterior column reconstruction (ACR). The aim of this study, however, was to assess feasibility, outcome and potential pitfalls of monosegmental ACR using a VBRD. In addition, clinical and radiological outcome of monosegmental ACR was related to that of bisegmental ACR using the same thoracoscopic technique. ⋯ This study indicates that monosegmental ACR using a VBRD is feasible in thoracolumbar burst fractures if the inferior endplate is intact (incomplete burst fractures) or features only a single simple split fracture line (burst-split fractures). If the two identified pitfalls are avoided, monosegmental ACR may be a viable alternative to bisegmental ACR in selected thoracolumbar burst fractures to spare a motion segment and to reduce the distance for bony fusion.
-
Arch Orthop Trauma Surg · Jul 2018
Femoral tunnel widening is associated with tunnel malposition but not with clinical failure after medial patellofemoral ligament reconstruction with a free gracilis tendon graft.
MPFL reconstruction is widely and successfully used for treating patella instability, either as a standalone procedure or in combination. Although different techniques allow for MPFL reconstruction, the use of a free tendon graft is one of the most commonly used. The phenomenon of tunnel widening or tunnel enlargement is well described in ACL reconstruction, but so far only little effort has been put into evaluating this phenomenon after MPFL reconstruction. ⋯ Tunnel enlargement after MPFL reconstruction with a free gracilis tendon graft seems to be connected to mechanical overload due to a proximal malposition of the femoral tunnel. Interestingly, this did not influence clinical outcome as patients with tunnel enlargement showed better Kujala and IKDC scores.
-
Arch Orthop Trauma Surg · Jul 2018
Replacement options for the B2 glenoid in osteoarthritis of the shoulder: a biomechanical study.
Glenoid replacement in cases of severe glenoid retroversion (RV) or eccentric wear is challenging. The aim of this study was to evaluate different treatment methods under standardized conditions to assist surgeons in the decision-making process. ⋯ If sufficient bone stock is available, retroversion correction should be favored. Posterior augmented glenoids seem to be a suitable treatment option if complete correction of the retroversion is not possible without compromising the glenoid vault. Without correction of the retroversion, high failure rates were observed.
-
Arch Orthop Trauma Surg · Jul 2018
Slight under-correction following total knee arthroplasty for a valgus knee results in similar clinical outcomes.
Restoration of correct coronal alignment is one of the main goals of total knee arthroplasty (TKA). Traditionally, TKA has been considered successful when a neutral mechanical hip-knee-ankle (HKA) axis within 3° is achieved. Recent studies have reported no differences or improved clinical outcomes following a slight under-correction of the HKA axis for a varus knee. However, the influence of under-correction of a valgus knee has not been reported. This study investigated the influence of post-operative HKA alignment in TKA patients with valgus deformity on clinical outcomes. ⋯ III, Retrospective comparative study.
-
Arch Orthop Trauma Surg · Jul 2018
Role of an anatomically contoured plate and metal block for balanced stability between the implant and lateral hinge in open-wedge high-tibial osteotomy.
Open-wedge high tibial osteotomy (OWHTO) is a well-established surgical option for medial compartment osteoarthritis of the varus knee. The initial strength of the fixation plate is critical for successful correction maintenance and healing of the osteotomy site. This study was conducted to verify if a newly designed anatomical plate (LCfit) improves the stability of both the medial implant and lateral hinge area, as well as to evaluate how the metal block contributes to both medial and lateral stability. ⋯ The newly designed fixation system for OWHTO balanced the overall stress distribution and reduced stress at the lateral hinge area compared to that using a conventional fixation system. The addition of the metal block showed additional benefits for balanced stability between the medial implant and lateral hinge area. However, this conclusion could only be drawn using the FE model in this study. Therefore, further clinical studies are necessary to reveal the clinical effect of reduced lateral stress on the occurrence of the lateral hinge fracture and the biologic effect of the metal block on the healing of the medial cortex.