Archives of orthopaedic and trauma surgery
-
Arch Orthop Trauma Surg · Jul 2015
Open fixation of acute anterior glenoid rim fractures with bioresorbable pins: analysis of clinical and radiological outcome.
The purpose of this study was a detailed analysis of clinical and radiological results following open fixation of acute-traumatic, displaced anterior glenoid rim fractures with bioresorbable pins. ⋯ Bioresorbable pin fixation is a feasible and safe method of osteosynthesis for anterior glenoid rim fractures up to a glenoid defect size of about 35 % and enables immediate active range of motion. Good or excellent clinical outcome can be expected and glenohumeral stability is reliably restored. The most common mid- and long-term complication is occurrence or progression of osteoarthritis. The major benefits of bioresorbable pin fixation are redundancy of implant removal, minimal risk of implant-related complications and early functional rehabilitation.
-
Arch Orthop Trauma Surg · Jul 2015
Short-term results of the reverse Total Evolutive Shoulder System (TESS) in cuff tear arthropathy and revision arthroplasty cases.
The aim of this study was to evaluate the clinical and radiological outcome of the Total Evolutive Shoulder System (TESS) in patients with cuff tear arthropathy and patients in need of a revision arthroplasty. ⋯ Regarding the joint geometry, surgery with the TESS system provided adequate distalization and medialization of the humerus and the center of rotation. This corresponds to a good clinical outcome. The use of the surgical opportunity to implant the prosthesis with a relatively low neck-shaft angle might explain the low rates of scapular notching in our series. Regarding the case with a loosening of the humeral component, the surgeon should carefully indicate a stemless version for metaphyseal press-fit fixation in patients with revision arthroplasty.
-
Arch Orthop Trauma Surg · Jul 2015
Evaluation of spacer block technique using tensor device in unicompartmental knee arthroplasty.
Mobile-bearing unicompartmental knee arthroplasty (UKA) was designed so that flexion and extension gap adjustments could achieve isometric function of the ligaments throughout ROM to prevent complications. However, achieving accurate knee balancing using a spacer block technique remains difficult since determination of the thickness of the spacer block is determined according to the feeling of the individual surgeon's hand. The objective of the study was to investigate flexion and extension medial unicompartmental knee gap kinematics in mobile-bearing UKA and to reveal the accuracy of spacer block measurement technique using a gap tensor device. ⋯ These results suggest that gap measurement using a spacer block in UKA has the potential risk that the resulting extension gap may be smaller than the flexion gap. Surgeons should adjust the flexion and extension gaps with caution to achieve good ligament function when performing mobile-bearing UKA.
-
Arch Orthop Trauma Surg · Jul 2015
Case ReportsLaser engravings as reason for mechanical failure of titanium-alloyed total hip stems.
Two revisions of broken β-titanium total hip stems had to be performed in our hospital after 2 and 4 years in situ. Since both fractures were located at the level of a laser engraving, a failure analysis was conducted. ⋯ Laser engravings need to be reduced to a minimum of necessary information, and should be placed at locations with minimum mechanical load. Biomechanical analyses are recommended to identify less loaded areas in implant components to avoid such implant failures.
-
Arch Orthop Trauma Surg · Jul 2015
A new universal, standardized implant database for product identification: a unique tool for arthroplasty registries.
Every joint registry aims to improve patient care by identifying implants that have an inferior performance. For this reason, each registry records the implant name that has been used in the individual patient. In most registries, a paper-based approach has been utilized for this purpose. However, in addition to being time-consuming, this approach does not account for the fact that failure patterns are not necessarily implant specific but can be associated with design features that are used in a number of implants. Therefore, we aimed to develop and evaluate an implant product library that allows both time saving barcode scanning on site in the hospital for the registration of the implant components and a detailed description of implant specifications. ⋯ The implant library that was developed for the German Arthroplasty Registry allows not only on-site barcode scanning for the registration of the implant components but also its classification tree allows a sophisticated analysis regarding implant characteristics, regardless of brand or manufacturer. The database is maintained by the implant manufacturers, thereby allowing registries to focus their resources on other areas of research. The database might represent a possible global model, which might encourage harmonization between joint replacement registries enabling comparisons between joint replacement registries.