Journal of neuroimaging : official journal of the American Society of Neuroimaging
-
High-resolution three-dimensional (3D) post-contrast imaging of the brain is essential for comprehensive evaluation of inflammatory, neoplastic, and neurovascular diseases of the brain. 3D T1-weighted spin-echo-based sequences offer increased sensitivity for the detection of enhancing lesions but are relatively prolonged examinations. We evaluated whether a highly accelerated Wave-controlled aliasing in parallel imaging (Wave-CAIPI) post-contrast 3D T1-sampling perfection with application-optimized contrasts using different flip angle evolutions (T1-SPACE) sequence (Wave-T1-SPACE) was noninferior to the standard high-resolution 3D T1-SPACE sequence for visualizing enhancing lesions with comparable diagnostic quality. ⋯ Our findings show that Wave-T1-SPACE was noninferior to standard T1-SPACE for visualization of enhancing pathology and overall diagnostic quality with a three-fold reduction in acquisition time compared to the standard sequence. Wave-T1-SPACE may be used to accelerate 3D post-contrast T1-weighted spin-echo imaging without loss of clinically important information.
-
Meta Analysis Observational Study
Cyclical aspiration using a novel mechanical thrombectomy device is associated with a high TICI 3 first pass effect in large-vessel strokes.
Complete reperfusion (TICI 3) after the first thrombectomy attempt or first pass effect (FPE) is associated with best clinical outcomes in large-vessel occlusion (LVO) acute ischemic stroke. While endovascular therapy techniques have improved substantially, FPE remains low (24-30%), and new methods to improve reperfusion efficiency are needed. ⋯ Cyclical aspiration using the CLEARTM Aspiration System is safe, effective, and achieved a high TICI 3 FPE for large-vessel strokes.
-
Randomized Controlled Trial
Tapentadol and oxycodone affect resting-state functional brain connectivity: A randomized, placebo-controlled trial.
The changes in functional brain connectivity induced by treatment with analgesics are poorly investigated. Unfortunately, results from clinical studies investigating treatments in patients with pain are often confounded by co-medication and comorbidity. Thalamus is central in sensory processing, and we hypothesized that functional connectivity between thalamus and other brain areas in healthy volunteers was different in treatment with oxycodone, representing a pure opioid, compared to treatment with tapentadol, which has a dual effect on the opioidergic and adrenergic systems. ⋯ This study has shown that the functional connectivity between thalamus and other brain areas central in pain processing was different for the tapentadol and oxycodone treatments compared to placebo. This supports that the two treatments exert different mechanism of action. Further studies with larger sample sizes need to be carried out in order to validate this.
-
Cerebral vessel recanalization therapy, either intravenous thrombolysis or mechanical thrombectomy, is the main treatment that can significantly improve clinical outcomes after acute ischemic stroke. The degree of recanalization and cerebral reperfusion of the ischemic penumbra are dependent on cerebral hemodynamics. Currently, the main imaging modalities to assess reperfusion are MRI and CT perfusion. ⋯ This review summarizes the most relevant literature on the role of TCD in evaluating patients after reperfusion therapy. We also discuss the importance of performing TCD in the first few hours following thrombolytic therapy in identifying hyperperfusion syndrome and embolic signals, predicting recurrent stroke, and detecting reocclusions, all of which may help improve patient prognosis. We recommend TCD during the hyperacute phase of stroke in comprehensive stroke centers.
-
Review
Optic nerve sheath diameter assessment by neurosonology: A review of methodologic discrepancies.
Reported cutoff values of the optic nerve sheath diameter (ONSD) for the diagnosis of elevated intracranial pressure (ICP) are inconsistent. This hampers ONSD as a possible noninvasive bedside monitoring tool for ICP. Because the influence of methodological differences on variations in cutoff values is unknown, we performed a narrative review to identify discrepancies in ONSD assessment methodologies and to investigate their effect on reported ONSD values. ⋯ Based on our observations, we recommend to place ultrasound markers at the outer edges of the hyperechoic striped bands or at the transitions from the single dark region to the hyperechoic retrobulbar fat because these locations yielded the highest sensitivity of ONSD measurements for increased ICP.