Journal of magnetic resonance imaging : JMRI
-
J Magn Reson Imaging · Jun 2009
Multiecho time-resolved acquisition (META): a high spatiotemporal resolution Dixon imaging sequence for dynamic contrast-enhanced MRI.
To evaluate a new dynamic contrast-enhanced (DCE) imaging technique called multiecho time-resolved acquisition (META) for abdominal/pelvic imaging. META combines an elliptical centric time-resolved three-dimensional (3D) spoiled gradient-recalled echo (SPGR) imaging scheme with a Dixon-based fat-water separation algorithm to generate high spatiotemporal resolution volumes. ⋯ META is a promising high spatiotemporal resolution imaging sequence for capturing the fast dynamics of hyperenhancing hepatic lesions and provides robust fat suppression even at 3T.
-
J Magn Reson Imaging · Jun 2009
Diffusion-weighted echo-planar magnetic resonance imaging for the assessment of tumor cellularity in patients with soft-tissue sarcomas.
To investigate the eligibility of diffusion-weighted imaging (DWI) for the evaluation of tumor cellularity in patients with soft-tissue sarcomas. ⋯ DWI has proven useful for the assessment of tumor cellularity in soft-tissue sarcomas. In result, DWI may be used as a powerful noninvasive tool to monitor responses of cytotoxic treatment as reflected by changes in tumor cellularity.
-
J Magn Reson Imaging · Jun 2009
ToF-SWI: simultaneous time of flight and fully flow compensated susceptibility weighted imaging.
To perform systematic investigations on parameter selection of a dual-echo sequence (ToF-SWI) for combined 3D time-of-flight (ToF) angiography and susceptibility weighted imaging (SWI). ⋯ A dual-echo sequence (ToF-SWI) with full flow compensation of the second echo in a single scan is feasible. This sequence allows simultaneous visualization of intrinsically coregistered arteries and veins without spatial mis-registration of vessels caused by oblique flow and with minimal signal loss in arteries.
-
J Magn Reson Imaging · Jun 2009
Optimized high-resolution mapping of magnetization transfer (MT) at 3 Tesla for direct visualization of substructures of the human thalamus in clinically feasible measurement time.
To optimize contrast-to-noise and spatial resolution of a FLASH-based magnetization transfer (MT) protocol for visualization of substructures in human thalamus. ⋯ Semiquantitative MT saturation maps provide an enhanced intra-thalamic contrast. The borders and nuclear groups of the thalamus are reliably delineated; individual assignment of singular nuclei seems feasible.
-
J Magn Reson Imaging · Jun 2009
Comparative StudyMeasurement of deep gray matter perfusion using a segmented true-fast imaging with steady-state precession (True-FISP) arterial spin-labeling (ASL) method at 3T.
To study the feasibility of using the MRI technique of segmented true-fast imaging with steady-state precession arterial spin-labeling (True-FISP ASL) for the noninvasive measurement and quantification of local perfusion in cerebral deep gray matter at 3T. ⋯ Segmented True-FISP ASL is a practical and quantitative technique suitable to measure local tissue perfusion in cerebral deep gray matter at a high spatial resolution without the susceptibility artifacts commonly associated with EPI-based methods of ASL.