Elimination of residual aliasing artifact that resembles brain lesion on multi-oblique diffusion-weighted echo-planar imaging with parallel imaging using virtual coil acquisition.
Single-shot diffusion-weighted echo-planar imaging (ssDW-EPI) acquired with parallel imaging and a multi-oblique scan plane may suffer from residual aliasing artifacts, resembling lesions on the calculated apparent diffusion coefficient (ADC) map. ⋯ 1 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:1442-1453.
-
J Magn Reson Imaging · May 2020
Qualitative and Quantitative Reporting of a Unique Biparametric MRI: Towards Biparametric MRI-Based Nomograms for Prediction of Prostate Biopsy Outcome in Men With a Clinical Suspicion of Prostate Cancer (IMPROD and MULTI-IMPROD Trials).
Multiparametric MRI of the prostate has been shown to improve the risk stratification of men with an elevated prostate-specific antigen (PSA). However, long acquisition time, high cost, and inter-center/reader variability of a routine prostate multiparametric MRI limit its wider adoption. ⋯ A prediction model using qualitative IMPROD bpMRI findings demonstrated high accuracy for predicting SPCa in men with an elevated PSA. Online risk calculator: http://petiv.utu.fi/multiimprod/ Level of Evidence: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1556-1567.
-
J Magn Reson Imaging · Apr 2020
Fully automated localization of prostate peripheral zone tumors on apparent diffusion coefficient map MR images using an ensemble learning method.
Accurate detection and localization of prostate cancer (PCa) in men undergoing prostate MRI is a fundamental step for future targeted prostate biopsies and treatment planning. Fully automated localization of peripheral zone (PZ) PCa using the apparent diffusion coefficient (ADC) map might be clinically useful. ⋯ 4 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:1223-1234.
-
J Magn Reson Imaging · Apr 2020
Test-Retest Reliability of the Brain Metabolites GABA and Glx With JPRESS, PRESS, and MEGA-PRESS MRS Sequences in vivo at 3T.
The optimization of magnetic resonance spectroscopy (MRS) sequences allows improved diagnosis and prognosis of neurological and psychological disorders. Thus, to assess the test-retest and intersequence reliability of such MRS sequences in quantifying metabolite concentrations is of clinical relevance. ⋯ 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:1181-1191.
-
J Magn Reson Imaging · Apr 2020
Human Placenta Blood Flow During Early Gestation With Pseudocontinuous Arterial Spin Labeling MRI.
Noninvasive measurement of placental blood flow is the major technical challenge for predicting ischemic placenta (IPD). Pseudocontinuous arterial spin labeling (pCASL) MRI was recently shown to be promising, but the potential value in predicting the subsequence development of IPD is not known. ⋯ 2 TECHNICAL EFFICACY STAGE: 1 J. Magn. Reson. Imaging 2020;51:1247-1257.