Pulmonary MR perfusion at 3.0 Tesla using a blood pool contrast agent: Initial results in a swine model.
To prospectively evaluate the technical feasibility of a highly accelerated pulmonary MR perfusion protocol at 3.0T using a blood pool contrast agent in a swine model. ⋯ 3.0T pulmonary MR perfusion using a blood pool contrast agent in a swine model is feasible. The higher available signal-to-noise ratio (SNR) at 3.0T and the high T1 relaxivity of Gadomer-17 effectively support highly accelerated parallel acquisition, and improve the performance of time-resolved pulmonary MRA.
-
J Magn Reson Imaging · Jan 2007
Small hepatic lesions found on single-phase helical CT in patients with malignancy: diagnostic capability of breath-hold, multisection fluid-attenuated inversion-recovery (FLAIR) MR imaging using a half-fourier acquisition single-shot turbo spin-echo (HASTE) sequence.
To evaluate the diagnostic capability of breath-hold, multisection fluid-attenuated inversion-recovery (FLAIR) imaging using a half-Fourier acquisition single-shot turbo spin-echo (HASTE) sequence in combination with T2-weighted fast spin-echo (FSE) magnetic resonance (MR) sequences for small hepatic lesions found on CT in patients with malignancy. ⋯ FLAIR-HASTE is considered to be an effective sequence for differentiating hepatic cysts from liver metastases without the use of a contrast agent. With FLAIR-HASTE one can confidently diagnose small hepatic lesions found on CT in patients with a malignancy.
-
J Magn Reson Imaging · Jan 2007
Comparative StudyDiagnosis of breast tumors by contrast-enhanced MR imaging: comparison between the diagnostic performance of dynamic enhancement patterns and morphologic features.
To compare the diagnostic performance of breast lesions by the enhancement patterns and morphologic criteria on magnetic resonance imaging (MRI). ⋯ The analysis of the morphologic features of enhancing breast lesions alone showed higher diagnostic performance; therefore, signal intensity (SI) time-course data may not be needed to diagnose malignant breast lesions.
-
J Magn Reson Imaging · Jan 2007
Comparative StudyMRI of the lung: value of different turbo spin-echo, single-shot turbo spin-echo, and 3D gradient-echo pulse sequences for the detection of pulmonary metastases.
To compare the value of different MRI sequences of the lung for the detection of pulmonary metastases. ⋯ Conventional TSE sequences are more sensitive in depicting pulmonary metastases than single-shot TSE or 3D gradient-echo sequences. Respiratory and pulse triggering can improve lesion detection, but increases acquisition time substantially.
-
J Magn Reson Imaging · Jan 2007
Breast MRI lesion classification: improved performance of human readers with a backpropagation neural network computer-aided diagnosis (CAD) system.
To develop and test a computer-aided diagnosis (CAD) system to improve the performance of radiologists in classifying lesions on breast MRI (BMRI). ⋯ A CAD system based on lesion morphology and enhancement kinetics can improve the performance of human readers in classifying lesions on breast MRI.