Comparative StudyFlow resistances of disposable double-lumen, single-lumen, and Univent tubes.
To compare the airflow resistances of modern double-lumen, single-lumen, and Univent (Fuji Systems Corp; Tokyo, Japan) tubes. ⋯ Flow resistances of modern disposable double-lumen tubes are lower than commonly perceived. In most clinical situations, there will be no decrease in flow resistance when a Rusch or Sheridan double-lumen tube is replaced by a single-lumen tube.
-
J. Cardiothorac. Vasc. Anesth. · Apr 1998
Respiratory mechanics and gas exchange during one-lung ventilation for thoracic surgery: the effects of end-inspiratory pause in stable COPD patients.
To examine the effects of end-inspiratory pause (EIP) of different durations on pulmonary mechanics and gas exchange during one-lung ventilation (OLV) for thoracic surgery. ⋯ During the period of OLV in the lateral position of patients with preexisting pulmonary hyperinflation, the magnitude of PEEPi increased and oxygenation decreased significantly, whereas the efficacy of ventilation was not changed by the addition of an end-inspiratory pause to the ventilatory pattern. Because arterial oxygenation is affected by the presence of pulmonary hyperinflation, the method of ventilation should take into account the magnitude of preoperative pulmonary hyperinflation.