Journal of cardiothoracic and vascular anesthesia
-
Transcranial Doppler is a bedside procedure that measures linear cerebral blood flow velocity (CBFV) and the pulsatility index through the intracranial circulation. Transcranial color-coded duplex Doppler (TCCD) provides both CBFV and B-mode functions. In this review they are both referred to as brain ultrasound TCCD. ⋯ In these applications, TCCD can be used for the detection of cerebral vessel occlusion, estimation of cerebrovascular reactivity, right-to-left cardiac shunts, noninvasive estimation of cerebral perfusion and intracranial pressure, optic nerve sheath diameter, midline shift, hydrocephalus, and the presence of foreign objects. Finally, TCCD has a high accuracy in confirming total cerebral circulatory arrest and has been used as an ancillary test to support clinical diagnosis of brain death. Other indications for TCCD include assessment of collateral blood flow and embolization during carotid endarterectomy, assessment of patterns and extent of collateral circulation in severe stenosis or occlusion, assessment of patent foramen ovale/paradoxical embolism, assessment of arteriovenous malformations and studying their supply arteries and flow patterns, assessment of noncardiac right-to-left shunts, assessment of severe stenosis in the arteries of the circle of Willis, and assessment of vertebral artery dissection.