European radiology
-
It has been reported that 3D-FLAIR can reduce the flow artifact resulting from cerebrospinal fluid (CSF) at 1.5 T compared to 2D-FLAIR. Flow-related artifacts tend to be worse at 3 T than at 1.5 T. The purpose of this study was to compare the CSF flow artifacts of 2D-FLAIR and 3D-FLAIR sequences at 3 T in eight healthy volunteers. ⋯ The CSF in-flow artifact scores were significantly higher on axial 2D-FLAIR than on axial 3D-FLAIR MPR images in all areas except the bilateral sylvian fissures, and higher on sagittal 2D-FLAIR than on sagittal 3D-FLAIR MPR images in perimedullary, bilateral CP angle and suprasellar cisterns. The CSF-related flow artifacts were significantly reduced by 3D-FLAIR, while structures in the cistern were depicted more clearly, even at 3 T. Further study is necessary to compare the clinical efficacy between 2D-FLAIR and 3D-FLAIR in depicting subtle abnormalities.
-
The purpose of this study was to assess the therapeutic efficacy and immediate and long-term safety of expanded-tetrafluoroethylene covered stent-grafts for transjugular intrahepatic portosystemic shunts in patients with portal hypertension-related complications. A cohort of 56 patients suffering from severe portal hypertension-related complications underwent implantation of an expanded-polytetrafluoroethylene-covered stent-graft. All patients suffered from severe liver cirrhosis graded Child-Pugh A (n=8; 16%), B (n=13; 21%) or C (n=35; 63%). ⋯ Three of these four patients died within the 1st month after TIPS placement. A very high primary patency rate of TIPS can be obtained long-term after implantation of an e-PTFE-covered stent-graft, leading to a definitive resolution of portal hypertension-related complications. The incidence of TIPS-induced hepatic encephalopathy is acceptable.
-
Comparative Study
Simple models improve the discrimination of prostate cancers from the peripheral gland by T1-weighted dynamic MRI.
Evaluation of the accuracy of descriptive and physiological parameters calculated from signal intensity-time curves using T1-weighted dynamic contrast enhanced MRI (DCE MRI) to differentiate prostate cancers from the peripheral gland. Twenty-seven patients with prostate cancers were examined with DCE MRI prior radical prostatectomy. Regions of interest were defined in tumors and non-affected areas in the peripheral zone. ⋯ VD was higher in tumors than in the non-affected peripheral prostate (P=0.05). However, none of the dynamic parameters in carcinomas showed a significant correlation with VD or Gleason score. Although pharmacokinetic modeling in DCE MRI showed potential to discriminate prostate cancers from peripheral prostate tissue, descriptive parameters of the early signal enhancement after contrast media injection reached higher sensitivity and specificity.
-
Comparative Study
Traumatic injuries of the pelvis and thoracic and lumbar spine: does thin-slice multidetector-row CT increase diagnostic accuracy?
The objective is to evaluate different multidetector-row CT (MDCT) strategies for adequate classification of spinal and pelvic injuries. Seventy intubated patients after multiple trauma underwent conventional radiography (CR) and MDCT. Examinations included the pelvis (P), the lumbar spine (LS) and the thoracic spine (TS). ⋯ Fractures were identified by CT3R in 100% of cases, by CT5R in 95%, by CT3 in 90% [P]-100% [TS], by CT5 in 83.3% [LS]-90% [P] and by CR in 57.1% [TS]-87.2% [P]. Unstable fractures were identified in 100% by CT3R, CT5R and CT3, 85.7% [TS]-100% [P/LS] by CT5 and 57.1% [TS]-80% [P] by CR. Only overlapping thin-slice multiplanar reformation allows for an adequate classification of spinal and pelvic injuries and thus is highly emphasized in patients after severe blunt trauma.
-
The aim of this retrospective study was to emphasize the performances of spiral CT (HCT) and multidetector-row CT (MDCT) as very effective imaging modalities for the diagnosis of intestinal perforations caused by calcified alimentary foreign bodies. Eight sites of perforations of the ileum by ingested foreign bodies were found in seven patients--one patient presenting with two separate sites of perforation. The diagnosis was successfully made by HCT in four patients and MDCT in the remaining three. ⋯ In each patient, this identification was only possible thanks to the scrupulous analysis of very thin overlapping reconstructions obtained not only in the perforation sites (6/8 sites), but also through the entire abdomen (2/8 sites). Our report emphasizes the high performances of CTA and MDCT in identifying intestinal perforation caused by calcified alimentary foreign bodies. Moreover, the high specificity of the CT diagnosis made it possible to avoid surgerical exploration in three patients.