ASAIO journal : a peer-reviewed journal of the American Society for Artificial Internal Organs
-
Bioline-coated polymethylpentene (PMP) membrane oxygenators (MO) are used for extracorporeal membrane oxygenation (ECMO) to improve gas exchange in patients with severe acute respiratory distress syndrome (ARDS). However, in some patients, long-term durability is limited due to fibrous and cellular accumulations on the gas exchange surface which can increase resistance to blood flow and diffusion path. These surface deposits of PMP MO after removal were studied with scanning electron and fluorescence microscopy techniques. ⋯ A membranous structure composed of single cells and clusters of cells covered large areas of the PMP fibers. We assume that these cellular deposits lower the efficacy of ECMO. The identification of these cells could be a key for future therapeutic interventions and improvements in the development of MO.
-
Biography Historical Article
Michael Ellis DeBakey, M.D. September 7, 1908 to July 11, 2008.
-
Randomized Controlled Trial
Effect of different albumin concentrations in extracorporeal circuit prime on perioperative fluid status in young children.
This study examined the effects of different dosages of albumin priming for extracorporeal circuit (ECC) on perioperative fluid status and fluid management in young children. A total of 151 consecutive pediatric patients (2-36 months old) scheduled for open heart surgery, were divided into two groups randomly, to receive either a 3% albumin solution (L group, n = 68) or a 5% albumin (H group, n = 83). Perioperative fluid intake, urine output, blood loss, diuretic dosage, the use of allogeneic blood products, ultrafiltration, and daily balance were recorded for 24 hrs in intensive care unit (ICU). ⋯ No statistically significant differences were found between the two groups in blood loss and the amount of allogenic blood products infused, length of mechanical ventilation, ICU or hospital stay, complications, or mortality. Higher concentration of albumin prime in ECC showed decreased positive fluid balances, but produced less urine output and required more diuretic usage postoperatively. Thus, no significant clinical benefit resulted from the increased dosage.
-
This study aims to compare the Jostra HL-20 roller pump to the Medos DeltaStream DP1 rotary pump in terms of pressure and flow waveforms, as well as calculated energies based on pressure/flow relationships, in a simulated pediatric cardiopulmonary perfusion system. The flow rate was set at 1,000 ml/min for each pump, under both pulsatile and nonpulsatile perfusion modes. Mean arterial pressure (MAP) was maintained at 40 mm Hg. ⋯ The total hemodynamic energy was also significantly higher in the Medos rotary pump than the Jostra roller pump, under pulsatile perfusion. This pilot study suggests that the Medos DeltaStream DP1 rotary pump may produce greater hemodynamic energy levels and higher quality physiologic pressure/flow waveforms than the Jostra roller pump. Further investigation of the Medos DeltaStream DP1 rotary pump is necessary to evaluate hemodynamic energy generation under various pump settings, in contrast to different flow rates.
-
Comparative Study
Comparison of two different blood pumps on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant CPB model.
The purpose of this study was to compare two different blood pumps (Jostra roller pump vs. Medos deltastream DP1 rotary pump) on delivery of gaseous microemboli during pulsatile and nonpulsatile perfusion in a simulated infant cardiopulmonary bypass (CPB) model. The Jostra and Medos pump were used in parallel pattern. ⋯ The results of this study confirm that rotary pump could deliver less gaseous microemboli than roller pump at the postpump site when a fixed volume air was introduced into the venous line. Pulsatile flow could transfer more gaseous microemboli at the postpump site, no matter which blood pump was used. Only few gaseous microemboli appeared at the postfilter site at high flow rates with an open arterial filter purge line.