Transient and quasi-steady computational fluid dynamics study of a left ventricular assist device.
The HeartQuest continuous flow left ventricle assist device (LVAD) with a magnetically levitated impeller operates under highly transient flow conditions. Due to insertion of the in-flow cannula into the apex of the left ventricle, the inlet flow rate is transient because of ventricular contraction, and the pump's asymmetric circumferential configuration with five rotating blades forces blood intermittently through the pump to the great arteries. ⋯ A quasi-steady analysis was also conducted to evaluate the difference between the steady and transient analyses and demonstrate the significance of transient analysis, especially for transient rotational sliding interfaces transient simulations. This transient flow analysis can be applied generally in the design process of LVADs; it provides more reliable fluid forces and moments on the impeller for successful design of the magnetic suspension system and motor.
-
Comparative Study
Extensive coagulation monitoring in patients after implantation of the MicroMed Debakey continuous flow axial pump.
Ventricular assist device (VAD) implantation is associated with impaired primary hemostasis and thromboembolic complications. Recently, a new generation of implantable continuous flow axial pumps was introduced into clinical application. To study the potential thrombogenic properties of this type of pump, we applied extensive platelet monitoring was applied. ⋯ Platelet activation markers were upregulated in the postoperative period but were returned to preoperative levels after initiation of aspirin. In contrast to routine coagulation monitoring, platelet function tests reflect in detail the coagulation status of blood pump recipients and the efficiency of antiaggregation therapy. Aspirin and dipyridamole therapy in addition to oral anticoagulation using phenprocoumon may contribute to platelet function and clot mechanics restoration and is, therefore, recommended for patients after VAD implantation.
-
Randomized Controlled Trial Clinical Trial
PMEA coating of pump circuit and oxygenator may attenuate the early systemic inflammatory response in cardiopulmonary bypass surgery.
We investigated the effects of coating a cardiopulmonary bypass (CPB) circuit and oxygenator with poly-2-methoxy-ethyl acrylate (PMEA) on the systemic inflammatory response during and after CPB. Thirty patients undergoing elective cardiac surgery were randomized into three groups (each group n = 10): noncoated (group N), heparin coated (group H), and PMEA coated circuit and oxygenator (group X). Bradykinin (BK), complement 3 activation (C3a) and interleukin-6 (IL-6) levels were measured as early phase indicators of inflammatory response, as were maximum C reactive proteins (CRP) and white blood cell (WBC) levels. ⋯ A-a DO2 was lower at the end of and 3 hours after CPB in groups H and X than in group N (p < 0.05). Maximum CRP levels were lower in group X than in groups N (p < 0.05). This prospective study suggests that PMEA coated CPB may improve respiratory function and decrease systemic inflammatory response after cardiac surgery, possibly because this circuit is as biocompatible as heparin coated CPB circuit.
-
Comparative Study
Hemocompatibility of PMEA coated oxygenators used for extracorporeal circulation procedures.
An inflammatory response to cardiopulmonary bypass (CPB) caused by bioincompatibility of extracorporeal circuits is one of the major clinical issues in cardiac surgery. Recently a new coating material, poly-2-methoxyethylacrylate (PMEA), was developed to improve the biocompatibility of blood contacting surfaces. In a simulated cardiopulmonary bypass model, using fresh human whole blood, 15 membrane oxygenators (Capiox SX18, Terumo Corp., Tokyo, Japan) were compared. ⋯ Expression of genes encoding proinflammatory cytokines in monocytes was increased in all groups, with the lowest being in the PMEA coated group. PMEA coated CPB surfaces in an in vitro experimental model showed an improved thrombogenicity, reduced bradykinin release, less platelet activation and less proinflammatory cytokines gene expression in comparison with a noncoated group. The authors assume that PMEA coating may ameliorate some of intra- and postperfusion syndromes, particularly hypotension, unspecific inflammation, hyperfibrinolysis, and blood loss.
-
Case Reports
Clinical use of the abiomed BVS 5000 as a pulsatile extracorporeal membrane oxygenation unit.
The traditional extracorporeal membrane oxygenation circuit uses a centrifugal pump. These pumps require close monitoring and are subject to complications. In addition, they do not take advantage of the potential benefits of pulsatile flow. ⋯ This report describes a circuit in which an oxygenator is connected to a pulsatile ventricular assist device. Single and dual circuit configurations are illustrated. Recommendations for pulmonary care during support are also described.