Paediatric anaesthesia
-
Paediatric anaesthesia · Dec 2018
Observational StudyA retrospective observational study of acquired subglottic stenosis using low-pressure, high-volume cuffed endotracheal tubes.
The safety of cuffed endotracheal tubes in the neonatal and critically ill pediatric population continues to be questioned due to the theoretical risk of acquired subglottic stenosis. The incidence of acquired subglottic stenosis in the high-risk mixed surgical and medical critically ill pediatric cohort using high-volume, low-pressure cuffed endotracheal tube policy has not yet been described. The aim of our study was to describe and evaluate the use and complication rate of cuffed ETT's in our unit over a 5-year period. ⋯ We report no single case of acquired subglottic stenosis in our cohort that required major surgical correction from a cuffed endotracheal tube during a 5-year period. The introduction of a policy of appropriate placement and maintenance of low-pressure, high-volume cuffed endotracheal tubes in the pediatric critical care unit was not associated with an increased rate of endotracheal tube-related subglottic trauma.
-
Paediatric anaesthesia · Dec 2018
Review Meta AnalysisFrequency of medication error in pediatric anesthesia: A systematic review and meta-analytic estimate.
Clinical evidence shows that pediatric anesthesia patients are subject to a higher rate of life-threatening medical errors than their adult counterparts. Medication error in adult anesthesia is estimated to occur to 1 in 133 anesthetic administrations, but such a figure has not been determined for pediatric anesthesia patients. Individual studies of medication error in pediatric anesthesia have ranged from rates of 0.01% to 1.92% of anesthetic uses. The present study is a systematic review that employs a meta-analytic estimate to determine the rate of medication error in pediatric anesthesia. ⋯ The present systematic review revealed a medication error rate of 1 per 1250 anesthetic administrations in pediatric anesthesia. This result is significantly lower than would be expected given reported rates of medication error in adult anesthesia, which raises questions regarding the validity of research methods and reporting of medication error in pediatric anesthesia. Future investigations of medication error should employ methodologies other than self-reporting of error, such as retrospective chart review.
-
Paediatric anaesthesia · Dec 2018
Comparative StudyThe power of N-PASS, aEEG, and BIS in detecting different levels of sedation in neonates: A preliminary study.
Sedatives are essential drugs in every intensive care unit in order to ensure the patient's optimal level of comfort. Avoiding conditions of over- and under-sedation is a challenge in a neonatal intensive care setting. Drug administration could be optimized by the concomitant use of objective methods to assess the level of sedation. ⋯ While none of the three methods alone was able to precisely differentiate between different levels of sedation, we suggest that using a combination of amplitude-integrated Electroencephalogram and Neonatal Pain, Agitation and Sedation Scale can be useful to distinguish between light and deep sedation in neonatal patients.
-
Paediatric anaesthesia · Dec 2018
Randomized Controlled TrialComparative evaluation of CMAC and Truview picture capture device for endotracheal intubation in neonates and infants undergoing elective surgeries: A prospective randomized control trial.
Videolaryngoscopy has an established role in difficult airway management in adults. However, there is limited literature to support their efficacy in children. The Truview Picture Capture Device has shown promising results for endotracheal intubation in infants in the past. The CMAC videolaryngoscope has launched its novel infant Miller blade, but its performance has not been assessed clinically for routine intubation in infants and neonates. We hypothesized that the CMAC videolaryngoscope would reduce the total time to intubation as compared to the Truview Picture Capture Device in neonates and infants. ⋯ The CMAC Miller blade reduced the total time taken for tracheal intubation and intubation difficulty as compared to the Truview Picture Capture Device and may be a better tool for intubation in infants.