Paediatric anaesthesia
-
Paediatric anaesthesia · Apr 2018
Analysis of the impact of race on blood transfusion in pediatric scoliosis surgery.
Surgical correction of pediatric scoliosis is associated with significant blood loss. Minimizing estimated blood loss and blood transfusion is beneficial as transfusions have been associated with increased morbidity, including risk of surgical site infections, longer hospitalizations, and increased cost. Although there is evidence that African-American or Black adults are more likely to require intraoperative blood transfusion compared with Caucasian or White adults, the reasons for this difference are unclear. ⋯ Black race was independently associated with increased estimated blood loss, increased rate of blood transfusion, and increased amount of blood transfused during surgical correction of pediatric scoliosis. Further investigation is needed to better understand the etiology of the disparity and assess opportunities for improving outcomes.
-
Paediatric anaesthesia · Apr 2018
Distances from vocal cords to mid-trachea for optimizing endotracheal tubes depth markers according to gestational age.
Adequate endotracheal tube positioning in preterm infants is complicated by the short length of the airway. Distal markers were designed to help with the insertion of endotracheal tubes at an appropriate depth below the vocal cords. However, those markers are not standardized between manufacturers, each tube size displays only one (sometimes 2) markers to provide information for infants of various gestational ages, and indicated distances are often too long for extremely preterm infants. ⋯ The linear relationship between laryngo-tracheal size and gestational age offers the opportunity to revise endotracheal tube depth markers for the smallest patients. Trials comparing those suggested markers with those currently in use are needed before implementation.
-
Paediatric anaesthesia · Apr 2018
Observational StudyDura to spinal cord distance at different vertebral levels in children and its implications on epidural analgesia: A retrospective MRI-based study.
The distance from the dura to spinal cord is not uniform at different vertebral levels. The dura to spinal cord distance may be a critical factor in avoiding the potential for neurological injury caused by needle trauma after a dural puncture. Typically, the greater the dura to spinal cord distance, the larger the potential safety margin. The objective of our study is to measure dura to spinal cord distance at two thoracic levels T6 -7 , T9 -10 , and one lumbar level L1 -2 using MRI images. ⋯ The present study reports that the largest dura to spinal cord distance is found at the T5-6 level, and the shortest dura to spinal cord distance at the L1-2 level. There appears to be substantially more room in the dorsal subarachnoid space at the thoracic level. The risk of spinal cord damage resulting from accidental epidural needle advancement may be greater in the lumbar region due to a more dorsal location of the spinal cord in the vertebral canal compared to the thoracic region.