Paediatric anaesthesia
-
Paediatric anaesthesia · Apr 2010
Reduced air leakage by adjusting the cuff pressure in pediatric laryngeal mask airways during spontaneous ventilation.
Optimal inflation of the laryngeal mask airway (LMA) cuff should allow ventilation with low leakage volumes and minimal airway morbidity. Manufacturer's recommendations vary, and clinical end-points have been shown to be associated with cuff hyperinflation and increased leak around the LMA. However, measurement of the intra-cuff pressure of the LMA is not routine in most pediatric institutions, and the optimal intra-cuff pressure in the LMA has not been determined in clinical studies. ⋯ Using cuff manometry, an intra-cuff pressure of 40 cmH2O was associated with reduced leak around the LMA while higher (60 cmH2O) and lower (20 cmH2O) cuff pressures resulted in higher leak volumes during spontaneous ventilation. In spontaneously breathing children, reducing the intra-cuff pressure of pediatric-sized LMAs even below the manufacturers' recommendations allows ventilation with minimized leakage around the LMA cuff.
-
Paediatric anaesthesia · Apr 2010
Protective ventilation to reduce inflammatory injury from one lung ventilation in a piglet model.
To test the hypothesis that protective ventilation strategy (PVS) as defined by the use of low stretch ventilation (tidal volume of 5 ml x kg(-1) and employing 5 cm of positive end expiratory pressure (PEEP) during one lung ventilation (OLV) in piglets would result in reduced injury compared to a control group of piglets who received the conventional ventilation (tidal volume of 10 ml x kg(-1) and no PEEP). ⋯ Based on this model, PVS decreases inflammatory injury both systemically and in the lung tissue with no adverse effect on oxygenation, ventilation, or lung function.
-
OBJECTIVES & AIM: The purpose of this investigation was to examine children's anxiety across the perioperative setting. ⋯ Identification and prevention of anxiety in children can help prevent negative outcomes following surgery.
-
Paediatric anaesthesia · Mar 2010
ReviewPediatric models for adult target-controlled infusion pumps.
Target-controlled infusion (TCI) pumps currently do not satisfactorily cater for the pediatric population, particularly for those under 5 years. Growth and development are two major aspects of children not readily apparent in adults, and these two aspects influence clearance (CL) and volume of distribution (V). In simple terms, V determines initial dose, and CL determines infusion rate at steady state. ⋯ Organ function also affects clearance, and propofol clearance is reduced in neonates and infants after cardiac surgery. Although pharmacokinetics (PK) in children is receiving increasing attention and is eminently programmable into a TCI device, pharmacodynamic (PD) measures in children remain poorly defined, partly because the depth of anesthesia monitoring are inadequate. Both PK and PD are necessary for safe use of TCI pumps.