The clinical outcome of patients with symptomatic lumbar spinal stenosis (LSS) was assessed during a follow-up period of 2 years after X-Stop implantation. The X-Stop is the most commonly used interspinous distraction device in patients with neurogenic intermittent claudication due to LSS. Between 2003 and 2007, more than 1,000 patients were examined in our centre with symptoms of intermittent claudication due to spinal stenosis. ⋯ Concerning the operative technique, a minimally invasive implantation with preservation of the interspinous ligament is appropriate. Functional (upright-) MRI examinations were able to demonstrate the positional-dependent stenosis. If available, fMRI represents the most helpful radiologic examination in assessing the outcome of interspinous spacer implantation.
-
The aim of this study is to review our experience with the transoral surgical management of anterior craniovertebral junction (CVJ) lesions with particular attention to the decision making and to the indication for a consecutive stabilization. During 10 years (1998-2007), 52 consecutive patients presenting exclusively fixed anterior compression at the cervicomedullary junction underwent transoral surgery. Mean age was 55.85 years (range 17-75 years). ⋯ A successful surgery achieving a stable decompression at the CVJ is an expertise demanding procedure. It requires accurate preoperative evaluation and, appropriate choice of decompression technique and stabilization instruments. Enlarged transoral approaches (despite higher morbidity) are a supportive means in cases of severe basilar invagination, cranial extension of the lesion or limited jaw mobility.
-
The projectional nature of radiogram limits its amount of information about the instrumented spine. MRI and CT imaging can be more helpful, using cross-sectional view. However, the presence of metal-related artifacts at both conventional CT and MRI imaging can obscure relevant anatomy and disease. ⋯ However, on MRI imaging metallic implants may produce geometric distortion, the so-called susceptibility artifact. In conclusion, although 140 kV and high milliamperage second exposures are recommended for imaging patients with hardware, caution should always be exercised, particularly in children, young adults, and patients undergoing multiple examinations. MRI artifacts can be minimized by positioning optimally and correctly the examined anatomy part with metallic implants in the magnet and by choosing fast spin-echo sequences, and in some cases also STIR sequences, with an anterior to posterior frequency-encoding direction and the smallest voxel size.